Design improvements in TLD badge reader system: experiences with auto-TLD badge reader

A.S. Pradhan , R.R. Bihari
Radiation Protection and Environment 23 ( 1) 27 -30

2000
Parameters of Large Scale Production of Personnel Monitoring TLD Cards Based on CaSO4:Dy

A.S. Pradhan , A.K. Bakshi , K. Srivastava , R.R. Bihari
Radiation Protection Dosimetry 85 ( 1) 67 -70

6
1999
Thermal Quenching and Two Peak Method - Influence of Heating Rates in TLDs

A.S. Pradhan
Radiation Protection Dosimetry 65 ( 1) 73 -78

18
1996
Thermoluminescence Response of AL2O3:C to UV and Ionising Radiation

A.S. Pradhan , P.K. Dash Sharma , V.K. Shirva
Radiation Protection Dosimetry 64 ( 3) 227 -231

18
1996
Responses of CaSO4:Dy Teflon TLD Discs to Diagnostic X Rays for Entrance and Exit Beam Dosimetry

A.S. Pradhan , V.K. Shirva , P.K. Dash Sharma , V. Jayalakshmi
Radiation Protection Dosimetry 48 ( 4) 359 -362

4
1993
Application of Thermoluminescence Dosemeters for Personnel Monitoring in India

A.R. Lakshmanan , B. Chandra , A.S. Pradhan , S.J. Supe
Radiation Protection Dosimetry 17 49 -52

6
1986
Cooled Optically Stimulated Luminescence of TLDs for Radiation Dosimetry

A.S. Pradhan
Radiation Protection Dosimetry 29 ( 3) 213 -215

2
1989
A concave tray with divergent block for desired dose distribution around shielded region in megavoltage radiation therapy

J.S. Avadhani , A.S. Pradhan , A. Sankar , P.S. Viswanathan
Radiotherapy and Oncology 37 ( 1) 71 -73

1
1995
Extended X-ray absorption fine structure (EXAFS) study of CaSO4:Dy phosphors

D. Bhattacharyya , A.K. Bakshi , G. Ciatto , G. Aquilanti
Solid State Communications 137 ( 12) 650 -653

5
2006
Theoretical evaluation of dose distribution in product in radiation processing plants

Jain Reji George , A.S. Pradhan
Radiation Physics and Chemistry 77 ( 2) 186 -191

2
2008
13
2017
4
1983
Some Parameters of Low and High LET Radiation Dosimetry Using CaF2:Tm TLDs

A.S. Pradhan , R.C. Bhatt
Radiation Protection Dosimetry 6 175 -177

7
1983
Annealing and Re-usability of CaF2:Tm (TLD-300) Ribbons

A.S. Pradhan , K. Olthoff-Muenter , J. Rassow
Radiation Protection Dosimetry 9 ( 4) 273 -276

9
1984
Fast Neutron Thermoluminescent Response of CaF2:Tm (TLD-300): Influence of Encapsulating Material

A.S. Pradhan , J. Rassow , P. Meissner , K. Olthoff-Muenter
Radiation Protection Dosimetry 9 ( 4) 269 -272

5
1984
Ultraviolet and γ-ray induced TL emission spectrum of CaF2: Dy—Effect of temperature treatment

A.S. Pradhan , R.C. Bhatt
The International Journal of Applied Radiation and Isotopes 32 ( 3) 179

8
1981
The development of thin CaSO4:Dy teflon TL dosimeters for beta dosimetry in personnel monitoring.

A.R. Lakshmanan , Bhuwan Chandra , A.S. Pradhan , R.K. Kher
The International Journal of Applied Radiation and Isotopes 31 ( 2) 107 -110

11
1980