Risk of atrioesophageal fistula formation with contact force–sensing catheters

作者: Eric Black-Maier , Sean D. Pokorney , Adam S. Barnett , Emily P. Zeitler , Albert Y. Sun

DOI: 10.1016/J.HRTHM.2017.04.024

关键词: Atrial fibrillationAdverse effectAtrioesophageal fistulaFistulaSurgeryCatheter ablationMedicineAblationComplicationRadiofrequency ablation

摘要: … which involved CF-sensing catheters and 13 non–CF-sensing catheters. The percentage of … % for CF-sensing catheters (65 of 1202) and 0.9% for non–CF-sensing catheters (13 of 1487…

参考文章(26)
Andrea Natale, Vivek Y. Reddy, George Monir, David J. Wilber, Bruce D. Lindsay, H. Thomas McElderry, Charan Kantipudi, Moussa C. Mansour, Daniel P. Melby, Douglas L. Packer, Hiroshi Nakagawa, Baohui Zhang, Robert B. Stagg, Lee Ming Boo, Francis E. Marchlinski, Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. Journal of the American College of Cardiology. ,vol. 64, pp. 647- 656 ,(2014) , 10.1016/J.JACC.2014.04.072
Patrick Müller, Johannes-Wolfgang Dietrich, Philipp Halbfass, Aly Abouarab, Franziska Fochler, Atilla Szöllösi, Karin Nentwich, Markus Roos, Joachim Krug, Anja Schade, Andreas Mügge, Thomas Deneke, None, Higher incidence of esophageal lesions after ablation of atrial fibrillation related to the use of esophageal temperature probes Heart Rhythm. ,vol. 12, pp. 1464- 1469 ,(2015) , 10.1016/J.HRTHM.2015.04.005
Muhammad R. Afzal, Jawaria Chatta, Anweshan Samanta, Salman Waheed, Morteza Mahmoudi, Rachel Vukas, Sampath Gunda, Madhu Reddy, Buddhadeb Dawn, Dhanunjaya Lakkireddy, Use of contact force sensing technology during radiofrequency ablation reduces recurrence of atrial fibrillation: A systematic review and meta-analysis Heart Rhythm. ,vol. 12, pp. 1990- 1996 ,(2015) , 10.1016/J.HRTHM.2015.06.026
Mohammed Shurrab, Luigi Di Biase, David F. Briceno, Anna Kaoutskaia, Saleem Haj‐Yahia, David Newman, Ilan Lashevsky, Hiroshi Nakagawa, Eugene Crystal, Impact of Contact Force Technology on Atrial Fibrillation Ablation: A Meta‐Analysis Journal of the American Heart Association. ,vol. 4, ,(2015) , 10.1161/JAHA.115.002476
A.Marc Gillinov, Gosta Pettersson, Thomas W. Rice, Esophageal injury during radiofrequency ablation for atrial fibrillation The Journal of Thoracic and Cardiovascular Surgery. ,vol. 122, pp. 1239- 1240 ,(2001) , 10.1067/MTC.2001.118041
ARAVINDA THIAGALINGAM, ANDRE D’AVILA, LORI FOLEY, J. LUIS GUERRERO, HENDRIK LAMBERT, GIOVANNI LEO, JEREMY N. RUSKIN, VIVEK Y. REDDY, Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter. Journal of Cardiovascular Electrophysiology. ,vol. 21, pp. 806- 811 ,(2010) , 10.1111/J.1540-8167.2009.01693.X
Sheldon M. Singh, Andre d’Avila, Steve K. Singh, Paul Stelzer, Eduardo B. Saad, Allan Skanes, Arash Aryana, Jason S. Chinitz, Robert Kulina, Marc A. Miller, Vivek Y. Reddy, Clinical outcomes after repair of left atrial esophageal fistulas occurring after atrial fibrillation ablation procedures Heart Rhythm. ,vol. 10, pp. 1591- 1597 ,(2013) , 10.1016/J.HRTHM.2013.08.012
JENNIFER E. CUMMINGS, CONOR D. BARRETT, KENNETH N. LITWAK, LUIGI DI BIASE, PUNAM CHOWDHURY, SEIL OH, CHI KEONG CHING, WALID I. SALIBA, ROBERT A. SCHWEIKERT, J. DAVID BURKHARDT, SHARI DE MARCO, LUCIANA ARMAGANIJAN, ANDREA NATALE, Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: comparison between 8 mm tip and open irrigation catheters. Journal of Cardiovascular Electrophysiology. ,vol. 19, pp. 641- 644 ,(2008) , 10.1111/J.1540-8167.2008.01130.X
Sheldon M. Singh, Andre d'Avila, Shephal K. Doshi, William R. Brugge, Rudolph A. Bedford, Theofanie Mela, Jeremy N. Ruskin, Vivek Y. Reddy, Esophageal Injury and Temperature Monitoring During Atrial Fibrillation Ablation Circulation-arrhythmia and Electrophysiology. ,vol. 1, pp. 162- 168 ,(2008) , 10.1161/CIRCEP.108.789552
Kasturi K. Ghia, Aman Chugh, Eric Good, Frank Pelosi, Krit Jongnarangsin, Frank Bogun, Fred Morady, Hakan Oral, A nationwide survey on the prevalence of atrioesophageal fistula after left atrial radiofrequency catheter ablation Journal of Interventional Cardiac Electrophysiology. ,vol. 24, pp. 33- 36 ,(2009) , 10.1007/S10840-008-9307-1