Influence of Voltage and Current on Arc Duration and Energy of DC Electromagnetic Contactor

作者: Kiyoshi Yoshida , Koichiro Sawa , Kenji Suzuki , Masaaki Watanabe , Hideki Daijima

DOI: 10.1109/HOLM.2011.6034775

关键词: Electric arcArc flashSeries and parallel circuitsMaterials scienceVoltage sourceElectromagneticsContactorArc (geometry)Electrical engineeringPre-chargeOptics

摘要: In this paper, experimental results were described for a general DC electromagnetic contactor switching under permanent magnet arc extinguishing. The experiment circuit was series of source voltage E, resistive load R and contactor. closed contact current Io adjusted by R. influence E on duration ta energy Ea break experimented. had been changed within range 50 -- 500V set from 5 to 30A at each E. Arc waveforms measured with digital oscilloscope. When high, became long. However, in 300V or more, shortens when is increased. 200V, not seen almost constant. 50V, long along Io, it clarified that magnets doesn't arc. shortening the 100V more. We think effect Lorentz's force different according Io. addition, are found large. Keywords contactor, discharge, duration, magnetic blast, energy,

参考文章(7)
Kiyoshi YOSHIDA, Koichiro SAWA, Kenji SUZUKI, Masaaki WATANABE, Influence of Voltage on Arc Characteristics and Electrode Mass Change of AgNi Contacts for Electromagnetic Contactors IEICE Transactions on Electronics. ,vol. 94, pp. 1395- 1401 ,(2011) , 10.1587/TRANSELE.E94.C.1395
Koichiro Sawa, Kiyoshi Yoshida, Masaaki Watanabe, Kenji Suzuki, Arc Characteristics and Electrode Mass Change of AgNi Contacts for Electromagnetic Contactors 2010 Proceedings of the 56th IEEE Holm Conference on Electrical Contacts. pp. 1- 6 ,(2010) , 10.1109/HOLM.2010.5619532
Tomohiro ATSUMI, Junya SEKIKAWA, Takayoshi KUBONO, Characteristics of Break Arcs Driven by Transverse Magnetic Field in a DC High-Voltage Resistive Circuit IEICE Transactions on Electronics. ,vol. 93, pp. 1393- 1398 ,(2010) , 10.1587/TRANSELE.E93.C.1393
B. Gengenbach, R. Michal, G. Horn, Erosion Characteristics of Silver-Based Contact Materials In a DC Contactor IEEE Transactions on Components, Hybrids, and Manufacturing Technology. ,vol. 8, pp. 64- 69 ,(1985) , 10.1109/TCHMT.1985.1136492
Sawa Koichiro, Yoshida Kiyoshi, Suzuki Kenji, Daijima Hideki, Watanabe Masaaki, Influence of Voltage on Arc Duration and Electrode Mass Change of AgNi Contacts for Electromagnetic Contactors IEICE Technical Report; IEICE Tech. Rep.. ,vol. 110, pp. 219- 222 ,(2010)
J.J. Shea, Modeling contact erosion in three phase vacuum contactors holm conference on electrical contacts. pp. 306- 314 ,(1997) , 10.1109/HOLM.1997.638056