摘要: Dengue is an emerging global health problem. There still no cure or vaccine for dengue infection. As a result, disease surveillance the only method to reduce burden effectively through virus containment. diagnosis test plays crucial role in due complexity of pathogenesis. With aid immunochromatography based rapid diagnostic (ICT-RDT), infection can be diagnosed accurately. However, major drawbacks this convenient RDT are lack accuracy (range from 11% 99%) and high cost per (>RM 40). ideal demand with characteristic low particular. In paper, integrated optical Mach-Zehnder interferometer (IO-MZI) biosensor proposed achieve RDT. The design IO-MZI had been carried out by using three dimensional finite difference beam propagation (3D-FD-BPM). estimated detection limit found 5.448×10−7 RIU which sufficient diagnostic.

参考文章(28)
Franz Brosinger, Herbert Freimuth, Manfred Lacher, Wolfgang Ehrfeld, Erk Gedig, Andreas Katerkamp, Friedrich Spener, Karl Cammann, A label-free affinity sensor with compensation of unspecific protein interaction by a highly sensitive integrated optical Mach–Zehnder interferometer on silicon Sensors and Actuators B-chemical. ,vol. 44, pp. 350- 355 ,(1997) , 10.1016/S0925-4005(97)00226-8
Khor Kang Nan, M Mohamad Shahimin, Optimisation of ion-exchanged channel waveguides for optical manipulation 2011 IEEE Regional Symposium on Micro and Nano Electronics. pp. 383- 387 ,(2011) , 10.1109/RSM.2011.6088366
A.H. Reshak, K.N. Khor, M.M. Shahimin, S.A.Z. Murad, Copper ion-exchanged channel waveguides optimization for optical trapping. Progress in Biophysics & Molecular Biology. ,vol. 112, pp. 118- 123 ,(2013) , 10.1016/J.PBIOMOLBIO.2013.05.003
Lee Ching Ng, Challenges in dengue surveillance and control Western Pacific Surveillance and Response. ,vol. 2, pp. e1- e1 ,(2011) , 10.5365/WPSAR.2011.2.2.001
Khor Kang Nan, M.M. Shahimin, F.R.M. Adikan, Optimization of Silicon Nitride Y-Branch Optical Waveguide for Evanescent Field Biosensor Advanced Materials Research. pp. 1183- 1188 ,(2014) , 10.4028/WWW.SCIENTIFIC.NET/AMR.875-877.1183
K. Misiakos, E. Makarona, I. Raptis, A. Salapatas, A. Psarouli, S. Kakabakos, P. Petrou, M. Hoekman, R. Stoffer, K. Tukkiniemi, G. Jobst, Monolithic silicon interferometric optoelectronic devices for label-free multi-analyte biosensing applications Proceedings of SPIE. ,vol. 8629, pp. 862906- ,(2013) , 10.1117/12.2001791
L. M. Lechuga, K. Zinoviev, L. Fernández, J. Elizalde, O. E. Hidalgo, C. Dominguez, Biosensing microsystem platforms based on the integration of Si Mach-Zehnder interferometer, microfluidics and grating couplers Silicon Photonics IV. ,vol. 7220, ,(2009) , 10.1117/12.809166
P. Prabhathan, V. M. Murukeshan, Zhang Jing, Pamidighantam V. Ramana, Compact SOI nanowire refractive index sensor using phase shifted Bragg grating. Optics Express. ,vol. 17, pp. 15330- 15341 ,(2009) , 10.1364/OE.17.015330