Comparison of Biotribology of Swine Compact Bone Against UHMWPE

作者: Qing-liang WANG , Shi-rong GE

DOI: 10.1016/S1006-1266(07)60028-5

关键词: Serum proteinComparative testAbrasiveLubricationMetallurgyCompact boneTribometerAdhesive wearMaterials scienceTribology

摘要: Abstract A pin-on-disk tribometer was used, in a comparative test to observe the tribological behavior of swine femoral bone against UHMWPE with dry friction, physiological water and human plasma lubrication. The wear mechanisms bones were investigated by SEM. experimental results these tests demonstrated that both friction coefficient rate lowest when lubrication used. mechanism compact mainly fatigue corrosive under abrasive For UHMWPE, adhesive plastic deformation serious ploughing fracture lubrication, fine An analysis nitrogen elements on surface indicated content worn areas 16 times higher than unworn areas, which proved serum protein deposition occurred areas.

参考文章(13)
Steven T Woolson, Noman Q Khan, Referral Patterns of Hip Pain in Patients Undergoing Total Hip Replacement Orthopedics. ,vol. 21, pp. 123- 126 ,(1998) , 10.3928/0147-7447-19980201-05
David R. Haynes, Susan D. Rogers, Donald W. Howie, Mark J. Pearcy&NA;, Barrie Vernon-Roberts, Drug inhibition of the macrophage response to metal wear particles in vitro. Clinical Orthopaedics and Related Research. ,vol. 323, pp. 316- 326 ,(1996) , 10.1097/00003086-199602000-00045
Margaret A McGee, Donald W Howie, Kerry Costi, David R Haynes, Corinna I Wildenauer, Mark J Pearcy, Jean D McLean, Implant retrieval studies of the wear and loosening of prosthetic joints: a review Wear. ,vol. 241, pp. 158- 165 ,(2000) , 10.1016/S0043-1648(00)00370-7
Shirong Ge, Qingliang Wang, Dekun Zhang, Hua Zhu, Dangsheng Xiong, Chuanhui Huang, Xiaolong Huang, Friction and wear behavior of nitrogen ion implanted UHMWPE against ZrO2 ceramic Wear. ,vol. 255, pp. 1069- 1075 ,(2003) , 10.1016/S0043-1648(03)00269-2
Wei-Bor Tsai, John M. Grunkemeier, Thomas A. Horbett, Human plasma fibrinogen adsorption and platelet adhesion to polystyrene Journal of Biomedical Materials Research. ,vol. 44, pp. 130- 139 ,(1999) , 10.1002/(SICI)1097-4636(199902)44:2<130::AID-JBM2>3.0.CO;2-9
Jens B. Retpen, Jens-Erik Varmarken, Niels D. Rock, J. Steen Jensen, Unsatisfactory results after repeated revision of hip arthroplasty. 61 cases followed for 5 (1-10) years. Acta Orthopaedica Scandinavica. ,vol. 63, pp. 120- 127 ,(1992) , 10.3109/17453679209154807
R. M. V. Pidaparti, B. A. Merril, N. A. Downton, Fracture and material degradation properties of cortical bone under accelerated stress Journal of Biomedical Materials Research. ,vol. 37, pp. 161- 165 ,(1997) , 10.1002/(SICI)1097-4636(199711)37:2<161::AID-JBM3>3.0.CO;2-P
Yen-Shuo Liao, Paul D. Benya, Harry A. McKellop, Effect of protein lubrication on the wear properties of materials for prosthetic joints. Journal of Biomedical Materials Research. ,vol. 48, pp. 465- 473 ,(1999) , 10.1002/(SICI)1097-4636(1999)48:4<465::AID-JBM10>3.0.CO;2-Y