Arterial tonometry: Review and analysis

作者: Gary M. Drzewiecki , Julius Melbin , Abraham Noordergraaf

DOI: 10.1016/0021-9290(83)90037-4

关键词: Experimental workStandardizationEngineering drawingArterial tonometrySensitivity (control systems)Control engineeringEngineering

摘要: A review is presented of the field arterial tonometry and problems involved with its application. second generation model developed which interprets most difficulties encountered in previous experimental work. The also identifies barriers that must be overcome to allow become a practical technique for obtaining measurement continuous, absolute blood pressure. Problems addressed include those calibration, positioning sensitivity, design standardization, material properties vascular loading characteristics. Theoretical studies provide support application basic biomechanical concepts solution these suggest required features.

参考文章(25)
A Transducer for the Continuous External Measurement of Arterial Blood Pressure Ire Transactions on Bio-medical Electronics. ,vol. 10, pp. 73- 81 ,(1963) , 10.1109/TBMEL.1963.4322794
P D Stein, E F Blick, Arterial tonometry for the atraumatic measurement of arterial blood pressure. Journal of Applied Physiology. ,vol. 30, pp. 593- 596 ,(1971) , 10.1152/JAPPL.1971.30.4.593
Nicolaas Westerhof, Abraham Noordergraaf, Arterial viscoelasticity: a generalized model. Effect on input impedance and wave travel in the systematic tree. Journal of Biomechanics. ,vol. 3, pp. 357- 379 ,(1970) , 10.1016/0021-9290(70)90036-9
Paul D. Stein, Edward F. Blick, The potential usefulness of arterial tonometry for the measurement of instantaneous changes of arterial blood pressure. JAAMI: Journal of the Association for the Advancement of Medical Instrumentation. ,vol. 6, pp. 272- 275 ,(1972)
Haruka Okino, Measurement of intraluminal pressure from external pressure with strain transducers Journal of Applied Physiology. ,vol. 19, pp. 546- 549 ,(1964) , 10.1152/JAPPL.1964.19.3.546
Rao S, Raines Jk, Jaffrin My, A noninvasive pressure-pulse recorder: development and rationale. Medical instrumentation. ,vol. 7, pp. 245- ,(1973)
H. N. Sabbah, P. D. Stein, Semi-invasive method for instantaneous and phasic measurement of arterial blood pressure. Medical instrumentation. ,vol. 10, pp. 189- 192 ,(1976)
Novotney Rl, Arzbaecher Rc, Non-invasive measurement of the arterial pressure contour in man. Bibliotheca cardiologica. pp. 63- ,(1973)
Maynard Ramsey, Noninvasive automatic determination of mean arterial pressure Medical and Biological Engineering and Computing. ,vol. 17, pp. 11- 18 ,(1979) , 10.1007/BF02440948