Evaluation of the Red Emitting ${\rm Gd}_{2}{\rm O}_{2}{\rm S}\!\!:\!\!{\rm Eu}$ Powder Scintillator for Use in Indirect X-Ray Digital Mammography Detectors

作者: C. M. Michail , G. P. Fountos , I. G. Valais , N. I. Kalyvas , P. F. Liaparinos

DOI: 10.1109/TNS.2011.2162002

关键词: Light scatteringOptical transfer functionOpticsDetective quantum efficiencyAttenuationScintillatorDigital imagingLuminescenceDigital mammographyOptoelectronicsPhysics

摘要: The aim of the present study was to investigate imaging transfer characteristics and luminescence efficiency (XLE) Gd2O2S:Eu powder scintillator for use in X-ray mammography detectors. emits red part visible spectrum, having very good spectral compatibility with optical sensors employed digital systems. Three scintillating screens, coating thicknesses 33.1, 46.4 63.1 mg/cm2 , were prepared our laboratory. performance these screens assessed by experimental determination modulation function (MTF), noise (NTF) detective quantum (DQE) as well a single index image quality parameter such information capacity (IC). A theoretical model, describing radiation light transfer, used fit MTF data. This has allowed estimation attenuation coefficients scintillator. In addition, previously validated Monte Carlo code, based on properties Mie scattering theory, estimate detection efficiency, Swank factor zero frequency DQE Results showed that exhibits high values, which are comparable those commercially Gd2O2S:Tb screen. addition shows (effective gain) CCDs recently introduced CMOS Considering parameters results, this material can potentially be considered

参考文章(49)
Wilson J. Rugh, Linear System Theory ,(1992)
Panagiotis F. Liaparinos, Ioannis S. Kandarakis, Dionisis A. Cavouras, Harry B. Delis, George S. Panayiotakis, Monte Carlo study on the imaging performance of powder Lu2SiO5:Ce phosphor screens under x-ray excitation: Comparison with Gd2O2S:Tb screens Medical Physics. ,vol. 34, pp. 1724- 1733 ,(2007) , 10.1118/1.2724065
H Kanamori, M Matsumoto, The information spectrum as a measure of radiographic image quality and system performance Physics in Medicine and Biology. ,vol. 29, pp. 303- 313 ,(1984) , 10.1088/0031-9155/29/4/001
Christos. M. Michail, Ioannis G. Valais, Adrianos E. Toutountzis, Nektarios E. Kalyvas, George P. Fountos, Stratos L. David, Ioannis S. Kandarakis, George S. Panayiotakis, Light Emission Efficiency of ${\rm Gd}_{2} {\rm O} _{2} {\rm S}\!\!\!:\!\!\!{\rm Eu}$ (GOS:Eu) Powder Screens Under X-Ray Mammography Conditions IEEE Transactions on Nuclear Science. ,vol. 55, pp. 3703- 3709 ,(2008) , 10.1109/TNS.2008.2007562
P. Liaparinos, I. Valais, D. Nikolopoulos, N. Kalivas, A. Toutountzis, D. Cavouras, I. Kandarakis, G. Panayiotakis, C. Michail, S. David, Evaluation of the imaging performance of LSO powder scintillator for use in X-ray mammography Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. ,vol. 580, pp. 558- 561 ,(2007) , 10.1016/J.NIMA.2007.05.234
P Monnin, D Gutierrez, S Bulling, D Lepori, J-F Valley, F R Verdun, A comparison of the performance of modern screen-film and digital mammography systems. Physics in Medicine and Biology. ,vol. 50, pp. 2617- 2631 ,(2005) , 10.1088/0031-9155/50/11/012
G. W. Ludwig, X‐Ray Efficiency of Powder Phosphors Journal of The Electrochemical Society. ,vol. 118, pp. 1152- 1159 ,(1971) , 10.1149/1.2408271
Aldo Badano, Robert M. Gagne, Brandon D. Gallas, Robert J. Jennings, Jonathan S. Boswell, Kyle J. Myers, Lubberts effect in columnar phosphors. Medical Physics. ,vol. 31, pp. 3122- 3131 ,(2004) , 10.1118/1.1796151