作者: Abla M. Zayed , Alberto A. Sagues
DOI: 10.1016/0010-938X(90)90210-V
关键词: Corrosion 、 Cathodic protection 、 Composite material 、 Dielectric spectroscopy 、 Electrical impedance 、 Electrochemical corrosion 、 Materials science 、 Carbon steel 、 Metallurgy 、 Epoxy 、 Metal
摘要: The corrosion of manufactured epoxy-coated reinforcing steel with intentional surface damage in a naturally aerated NaCl solution was investigated. progression as function exposure time studied electrochemical impedance spectroscopy (EIS). Impedance diagrams were roughly semicircular large apparent constant. Integrated rates from nominal charge-transfer resistance evaluations reasonable agreement direct metallographic measurements metal loss at the end exposure. results interpreted transmission-line EIS model, proposing that cathodic reactions took place external, semiconductive products.