作者: C.Y. Kaplan , M.R. Wexler , S.G. Sandler
DOI: 10.1016/0305-4179(79)90029-9
关键词: Anesthesia 、 Red blood cell 、 Serology 、 Medicine 、 Plasma transfusions 、 In patient 、 Surgery 、 Haemolytic reaction 、 Plasma therapy 、 Severe burn 、 Complication 、 Critical Care and Intensive Care Medicine 、 Emergency medicine 、 General Medicine
摘要: Abstract Plasma transfusions in a patient with severe burn injuries transiently neutralized Lewis blood group antibodies and obscured the serological incompatibility of unit red cell (RBC) concentrate. An acute haemolytic reaction occurred 6 days later when RBCs were transfused. The case illustrates an unusual complication plasma therapy which may be prevented by repeating compatibility tests fresh specimens patients receiving multiple transfusion plasma, as well RBCs.