Complications of implanting three-piece C-loop posterior chamber lenses in the anterior chamber.

作者: Jared M Emery , Douglas D Koch , John F Liu

DOI: 10.3928/1542-8877-19881101-11

关键词: GlaucomaIntraocular lensSurgeryAnterior chamber angleCorneal edemaIntraocular lensesMacular edemaPeripheral anterior synechiaeMedicine

摘要: We have examined a total of four eyes in three patients who had undergone implantation three-piece C-loop posterior chamber intraocular lenses into the anterior chamber. All exhibited or more following complications: 1) loop encapsulation by peripheral synechiae; 2) recurrent iritis; 3) central displacement with corneal endothelial touch; 4) progressive cell loss and edema; 5) glaucoma; 6) cystoid macular edema. Intraocular lens removal was required all eyes, penetrating keratoplasty performed one. believe that these complications are attributable to inherent fallacies fixating open-loop angle.

参考文章(16)
Hamilton Rs, Prevention and management of the sunset syndrome. Transactions of the American Ophthalmological Society. ,vol. 81, pp. 276- 279 ,(1983)
Peter J. McDonnell, W. Richard Green, A.E. Maumenee, W. Jackson Iliff, Pathology of Intraocular Lenses in 33 Eyes Examined Postmortem Ophthalmology. ,vol. 90, pp. 386- 403 ,(1983) , 10.1016/S0161-6420(83)34558-9
Robert C. Maynor, Five cases of severe anterior chamber lens implant complications American Intra-Ocular Implant Society Journal. ,vol. 10, pp. 223- 224 ,(1984) , 10.1016/S0146-2776(84)80122-6
Kensaku Miyake, Masako Asakura, Hiroko Kobayashi, Effect of Intraocular Lens Fixation on the Blood-Aqueous Barrier American Journal of Ophthalmology. ,vol. 98, pp. 451- 455 ,(1984) , 10.1016/0002-9394(84)90130-2
Guy E. Knolle, Johnny Justice, William D. Spears, Iris Fixation Suturing of Intraocular Lenses Ophthalmology. ,vol. 88, pp. 407- 409 ,(1981) , 10.1016/S0161-6420(81)35018-0
S.A. Poleski, W.E. Willis, Angle-supported Intraocular Lenses: A Goniophotographic Study Ophthalmology. ,vol. 91, pp. 838- 840 ,(1984) , 10.1016/S0161-6420(84)34229-4
P. W. Smith, S. K. Wong, W. J. Stark, J. D. Gottsch, A. C. Terry, R. D. Bonham, Complications of semiflexible, closed-loop anterior chamber intraocular lenses. Archives of Ophthalmology. ,vol. 105, pp. 52- 57 ,(1987) , 10.1001/ARCHOPHT.1987.01060010058031
Wilhelm R.F. Böke, Heidelind C.A. Krüger, Causes and management of posterior chamber lens displacement American Intra-Ocular Implant Society Journal. ,vol. 11, pp. 179- 184 ,(1985) , 10.1016/S0146-2776(85)80022-7