作者: Svetlana Pushkar
DOI: 10.1061/(ASCE)AE.1943-5568.0000178
关键词: Environmental engineering 、 Impact assessment 、 Consumption (economics) 、 Greenhouse 、 Engineering 、 Environmental economics 、 Electricity generation 、 Coal 、 Value (economics) 、 Operational energy 、 Fossil fuel
摘要: AbstractFor environmental evaluation of building operational energy, greenhouse and acidic gases are typically used as appropriate measures. This approach can lead to the loss additional information concerning other carbon fuel–relevant impacts, such carcinogenic substances, fossil fuels, land users. The objective this study is analyze three different levels evaluation: (1) dioxide (CO2) emission (inventory), (2) impacts (midpoint), (3) damage (endpoint). A simple module (3×4×3m) facing east, north, south, west was studied. Eco-Indicator 99 (EI99), a comprehensive damage-oriented lifecycle impact assessment method, used. Coal primary fuel for electricity production. For each evaluations, an unpaired two-tailed t-test determine differences between all pairings in four cardinal orientations. On basis inventory midpoint separate optimizat...