Towards ultrahigh-resolution multi-reflection time-of-flight mass spectrometry at ISOLTRAP

作者: F Wienholtz , D Atanasov , S Kreim , V Manea , M Rosenbusch

DOI: 10.1088/0031-8949/2015/T166/014068

关键词: BunchesTime-of-flight mass spectrometryVoltageKinetic energyIonISOLTRAPAtomic physicsFull width at half maximumPhysicsMass spectrometry

摘要: The mass resolving power of the multi-reflection time-of-flight spectrometer ISOLTRAP was studied by monitoring 39K+ signals. A drift tube at center MR-ToF MS allows decreasing or increasing kinetic energy ion bunch, switching its potential when ions are traversing it. This offers possibility capturing and ejecting bunches controlling a single voltage so-called in-trap lift technique. It also changing trapped inside MS, offering way to optimize device. For fixed number 2000 laps corresponding total flight time about 30 ms, data accumulated for 100 experimental cycles, adding duration 10 s each spectrum. Without any subsequent corrections broadening effects, powers in excess 300 000 (FWHM) were obtained.

参考文章(32)
Hermann Wollnik, High-resolving mass spectrographs and spectrometers Hyperfine Interactions. ,vol. 235, pp. 61- 75 ,(2015) , 10.1007/S10751-015-1191-3
Christian Jesch, Timo Dickel, Wolfgang R. Plaß, Devin Short, Samuel Ayet San Andres, Jens Dilling, Hans Geissel, Florian Greiner, Johannes Lang, Kyle G. Leach, Wayne Lippert, Christoph Scheidenberger, Mikhail I. Yavor, The MR-TOF-MS isobar separator for the TITAN facility at TRIUMF Hyperfine Interactions. ,vol. 235, pp. 97- 106 ,(2015) , 10.1007/S10751-015-1184-2
M. Rosenbusch, P. Ascher, D. Atanasov, C. Barbieri, D. Beck, K. Blaum, Ch. Borgmann, M. Breitenfeldt, R. B. Cakirli, A. Cipollone, S. George, F. Herfurth, M. Kowalska, S. Kreim, D. Lunney, V. Manea, P. Navrátil, D. Neidherr, L. Schweikhard, V. Somà, J. Stanja, F. Wienholtz, R. N. Wolf, K. Zuber, Probing the N = 32 Shell Closure below the Magic Proton Number Z = 20: Mass Measurements of the Exotic Isotopes52,53K Physical Review Letters. ,vol. 114, pp. 202501- ,(2015) , 10.1103/PHYSREVLETT.114.202501
M. Mukherjee, D. Beck, K. Blaum, G. Bollen, J. Dilling, S. George, F. Herfurth, A. Herlert, A. Kellerbauer, H. -J. Kluge, S. Schwarz, L. Schweikhard, C. Yazidjian, ISOLTRAP: An on-line Penning trap for mass spectrometry on short-lived nuclides European Physical Journal A. ,vol. 35, pp. 1- 29 ,(2008) , 10.1140/EPJA/I2007-10528-9
Kevin Lan, James W. Jorgenson, A hybrid of exponential and gaussian functions as a simple model of asymmetric chromatographic peaks Journal of Chromatography A. ,vol. 915, pp. 1- 13 ,(2001) , 10.1016/S0021-9673(01)00594-5
V. Manea, E. Minaya Ramirez, S. Naimi, D. Neidherr, M. Rosenbusch, L. Schweikhard, J. Stanja, F. Wienholtz, K. Zuber, R. N. Wolf, D. Beck, K. Blaum, Ch. Böhm, Ch. Borgmann, M. Breitenfeldt, N. Chamel, S. Goriely, F. Herfurth, M. Kowalska, S. Kreim, D. Lunney, Plumbing Neutron Stars to New Depths with the Binding Energy of the Exotic Nuclide82Zn Physical Review Letters. ,vol. 110, pp. 041101- ,(2013) , 10.1103/PHYSREVLETT.110.041101
A. Piechaczek, V. Shchepunov, H.K. Carter, J.C. Batchelder, E.F. Zganjar, S.N. Liddick, H. Wollnik, Y. Hu, B.O. Griffith, Development of a high resolution isobar separator for study of exotic decays Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms. ,vol. 266, pp. 4510- 4514 ,(2008) , 10.1016/J.NIMB.2008.05.149
A. Perry, P. N. Ostroumov, A. Barcikowski, C. Dickerson, S. A. Kondrashev, B. Mustapha, G. Savard, Design of the low energy beam transport line between CARIBU and the EBIS charge breeder PROCEEDINGS OF THE XII INTERNATIONAL SYMPOSIUM ON ELECTRON BEAM ION SOURCES AND TRAPS. ,vol. 1640, pp. 68- 79 ,(2015) , 10.1063/1.4905401
A. N. Verentchikov, Multireflection Planar Time-of-Flight Mass Analyzer. II: The High-Resolution Mode Technical Physics. ,vol. 50, pp. 82- 86 ,(2005) , 10.1134/1.1854828