Setup error with and without image guidance using two canine intracranial positioning systems for radiation therapy.

作者: Celina Y. Morimoto , Monique N. Mayer , Narinder Sidhu , Rachel Bloomfield , Cheryl L. Waldner

DOI: 10.1111/VCO.12584

关键词: Positioning systemResidualFiducial markerComputed tomographyIn patientImage guidanceClinical treatmentRadiation therapyBiomedical engineeringComputer science

摘要: … Equipment included a four degrees-of-freedom couch capable of 1 mm translational moves. Six dog cadavers were positioned 24 times as for clinical treatment in a head re-positioner (…

参考文章(16)
L.R. Griffin, M.W. Nolan, L.E. Selmic, E. Randall, J. Custis, S. LaRue, Stereotactic radiation therapy for treatment of canine intracranial meningiomas. Veterinary and Comparative Oncology. ,vol. 14, ,(2016) , 10.1111/VCO.12129
MONIQUE N. MAYER, CHERYL L. WALDNER, KIRSTEN M. ELLIOT, NARINDER SIDHU, Comparison of interfractional variation in canine head position using palpation and a head-repositioning device. Veterinary Radiology & Ultrasound. ,vol. 51, pp. 472- 476 ,(2010) , 10.1111/J.1740-8261.2010.01672.X
Yuki Nemoto, Takuya Maruo, Yasuhiro Fukuyama, Shinpei Kawarai, Takuo Shida, Tomohiro Nakayama, A NOVEL SUPPORT DEVICE FOR HEAD IMMOBILIZATION DURING RADIATION THERAPY THAT IS APPLICABLE TO BOTH CATS AND DOGS Veterinary Radiology & Ultrasound. ,vol. 56, pp. 680- 686 ,(2015) , 10.1111/VRU.12274
A. W. Lightstone, Stanley H. Benedict, Frank J. Bova, Timothy D. Solberg, Robin L. Stern, Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group no. 68. Medical Physics. ,vol. 32, pp. 2380- 2398 ,(2005) , 10.1118/1.1945347
SARAH C. CHARNEY, WENDELL R. LUTZ, MARY K. KLEIN, PAMELA D. JONES, Evaluation of a head-repositioner and Z-plate system for improved accuracy of dose delivery. Veterinary Radiology & Ultrasound. ,vol. 50, pp. 323- 329 ,(2009) , 10.1111/J.1740-8261.2009.01544.X
Wendell Lutz, Ken R. Winston, Nasser Maleki, A system for stereotactic radiosurgery with a linear accelerator International Journal of Radiation Oncology Biology Physics. ,vol. 14, pp. 373- 381 ,(1988) , 10.1016/0360-3016(88)90446-4
Carla Rohrer Bley, Hans Blattmann, Malgorzata Roos, Andrea Sumova, Barbara Kaser-Hotz, Assessment of a radiotherapy patient immobilization device using single plane port radiographs and a remote computed tomography scanner. Veterinary Radiology & Ultrasound. ,vol. 44, pp. 470- 475 ,(2003) , 10.1111/J.1740-8261.2003.TB00487.X
Sonja Dieterich, Allison Zwingenberger, Katherine Hansen, Isabella Pfeiffer, Alain Théon, Michael S. Kent, INTER‐ AND INTRAFRACTION MOTION FOR STEREOTACTIC RADIOSURGERY IN DOGS AND CATS USING A MODIFIED BRAINLAB FRAMELESS STEREOTACTIC MASK SYSTEM Veterinary Radiology & Ultrasound. ,vol. 56, pp. 563- 569 ,(2015) , 10.1111/VRU.12271
Hege Kippenes, Patrick R. Gavin, Ronald D. Sande, Dennis Rogers, Vaughn Sweet, Comparison of the accuracy of positioning devices for radiation therapy of canine and feline head tumors. Veterinary Radiology & Ultrasound. ,vol. 41, pp. 371- 376 ,(2000) , 10.1111/J.1740-8261.2000.TB02090.X
MICHAEL S. KENT, IRA K. GORDON, INES BENAVIDES, PAUL PRIMAS, JACQUE YOUNG, Assessment of the accuracy and precision of a patient immobilization device for radiation therapy in canine head and neck tumors. Veterinary Radiology & Ultrasound. ,vol. 50, pp. 550- 554 ,(2009) , 10.1111/J.1740-8261.2009.01583.X