Chemotaxis, viability, and labeling stability of leukocytes labeled with (99m)Tc-exametazime stabilized with methylene blue.

作者: Manuel Roca , Fernando Iglesias , Víctor García , Félix Armero , Ma Carmen Díaz

DOI:

关键词: ChemistryMethylene blueIn vitroViability assayEosin YStainingChemotaxisTechnetium Tc 99m ExametazimeBiochemistryChromatographyTechnetium

摘要: The in vitro viability, chemotaxis, and labeling stability of leukocytes labeled using 99mTc-exametazime stabilized with methylene blue were evaluated compared those obtained nonstabilized 99mTc-exametazime. Methods: Two identical leukocyte populations, from 30 healthy donors, simultaneously freshly prepared 2-h-old following quality control techniques performed on each sample: eosin Y staining, chemotaxis radioassay, at 2 h after labeling. Results: Eosin staining showed a cell viability least 98% all samples, without significant statistical difference between the populations. Chemotactic indices prepared, unstabilized statistically greater than (z = 2.41; P

参考文章(13)
John I. Gallin, Robert A. Clark, Harry R. Kimball, Granulocyte chemotaxis: an improved in vitro assay employing 51 Cr-labeled granulocytes. Journal of Immunology. ,vol. 110, pp. 233- 240 ,(1973)
Denis English, J. A. Clanton, Evaluation of neutrophil labeling techniques using the chemotaxis radioassay. The Journal of Nuclear Medicine. ,vol. 25, pp. 913- 916 ,(1984)
A.M. Peters, S. Osman, B.L. Henderson, J.D. Kelly, H.J. Danpure, R.J. Hawker, H.J. Hodgson, R.D. Neirinckx, J.P. Lavender, Clinical experience with 99mTc-hexamethylpropylene-amineoxime for labelling leucocytes and imaging inflammation. The Lancet. ,vol. 328, pp. 946- 949 ,(1986) , 10.1016/S0140-6736(86)90601-X
K. O. Mang'era, H. P. Vanbilloen, C. W. Schiepers, A. M. Verbruggen, Stabilisation of high-activity99mTc-d,I-HMPAO preparations with cobalt chloride and their biological behaviour European Journal of Nuclear Medicine and Molecular Imaging. ,vol. 22, pp. 1163- 1172 ,(1995) , 10.1007/BF00800599
T. PRANGERE, A. D. BOWDEN, V. BEAUCHAT, M. T. CAULIER, P. ZIEGELS, D. HUGLO, R. D. PICKETT, M. STEINLING, A study of the behaviour of cobalt chloride during the labelling of leukocytes with 99Tcm-HMPAO stabilised in vitro by the addition of cobalt chloride solution. Nuclear Medicine Communications. ,vol. 18, pp. 258- 261 ,(1997) , 10.1097/00006231-199703000-00010
PeterS. Weisner, GaryR. Bower, LucindaA. Dollimore, AlanM. Forster, Brian Higley, AnthonyE. Storey, A method for stabilising technetium-99m exametazime prepared from a commercial kit European Journal of Nuclear Medicine and Molecular Imaging. ,vol. 20, pp. 661- 666 ,(1993) , 10.1007/BF00181755
J. C. HUNG, S. CHOWDHURY, D. W. MAHONEY, B. P. MULLAN, Radiolabelled mixed leukocytes and pure granulocytes with stabilized 99Tcm-exametazime. Nuclear Medicine Communications. ,vol. 19, pp. 981- 988 ,(1998) , 10.1097/00006231-199810000-00008
Joseph C. Hung, Wynn A. Volkert, Richard A. Holmes, Stabilization of technetium-99m—d,l-hexamethylpropyleneamine oxime (99mTc—d,l-HMPAO) using gentisic acid International Journal of Radiation Applications and Instrumentation. Part B. Nuclear Medicine and Biology. ,vol. 16, pp. 675- 680 ,(1989) , 10.1016/0883-2897(89)90137-2
M. Roca, J. Martín-Comín, W. Becker, M. Bernardo-Filho, B. Gutfilen, A. Moisan, M. Peters, E. Prats, M. Rodrigues, C. Sampson, A. Signore, H. Sinzinger, M. Thakur, A consensus protocol for white blood cells labelling with technetium-99m hexamethylpropylene amine oxime European Journal of Nuclear Medicine and Molecular Imaging. ,vol. 25, pp. 797- 799 ,(1998) , 10.1007/S002590050285