Co-Cr Head Roughness and its Effect on Wear of UHMWPE and XLPE Cups

作者: T. Donaldson , A. Massihi , J. G. Bowsher , I. C. Clarke

DOI: 10.1007/3-7985-1540-9_9

关键词: Composite materialWear particleMaterials scienceHead (vessel)Conventional polyethyleneCeramicSurface finishPolyethyleneBearing (mechanical)Femoral head

摘要: Crosslinked polyethylene appears to be a better hip bearing material than conventional polyethylene, but will it take us past the expected 20-year survival and into anticipated need for 30-year survivors? Knowing that sizeable percentage of Co-Cr femoral heads roughen in patient, XLPE is sensitive roughening, there are many doubts over long-term clinical use with cups. Wear studies at LLUMC suggest likely cost using larger head sizes young active patients, i.e. those requiring increase stability reduce dislocation. Therefore, we believe these higher activity patients extended expectations benefit from alternative surfaces such as ceramic on ceramic. In addition, four modes wear generation, impingement, backside etc., however, still know very little about processes XLPE, especially understanding changes particle concentrations.

参考文章(30)
P.S.M. Barbour, E. Ingham, D.C. Barton, J. Fisher, M.H. Stone, M.M. Endo, J.L. Tipper, Comparative wear and wear debris under three different counterface conditions of crosslinked and non‐crosslinked ultra high molecular weight polyethylene Bio-medical Materials and Engineering. ,vol. 11, pp. 23- 35 ,(2001)
Letitia Bradford, David A. Baker, Jove Graham, Arun Chawan, Michael D. Ries, Lisa A. Pruitt, Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. Journal of Bone and Joint Surgery, American Volume. ,vol. 86, pp. 1271- 1282 ,(2004) , 10.2106/00004623-200406000-00021
CHRISTIAN HEISEL, MAURICIO SILVA, MYLENE A. DELA ROSA, THOMAS P. SCHMALZRIED, Short-term in vivo wear of cross-linked polyethylene. Journal of Bone and Joint Surgery, American Volume. ,vol. 86, pp. 748- 751 ,(2004) , 10.2106/00004623-200404000-00012
Harry McKellop, Fu-wen Shen, Bin Lu, Patricia Campbell, Ronald Salovey, Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. Journal of Orthopaedic Research. ,vol. 17, pp. 157- 167 ,(1999) , 10.1002/JOR.1100170203
Ian C. Clarke, Thomas Donaldson, John G. Bowsher, Sam Nasser, Tomoki Takahashi, Current concepts of metal-on-metal hip resurfacing. Orthopedic Clinics of North America. ,vol. 36, pp. 143- 162 ,(2005) , 10.1016/J.OCL.2005.02.007
Harry McKellop, Fu-wen Shen, Will DiMaio, James G. Lancaster, Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. Clinical Orthopaedics and Related Research. ,vol. 369, pp. 73- 82 ,(1999) , 10.1097/00003086-199912000-00008
Hironobu Oonishi, Yoshinori Kadoya, Wear of high-dose gamma-irradiated polyethylene in total hip replacements Journal of Orthopaedic Science. ,vol. 5, pp. 223- 228 ,(2000) , 10.1007/S007760050155
David L. Scott, Pat A. Campbell, Christian D. McClung, Thomas P. Schmalzried, Factors contributing to rapid wear and osteolysis in hips with modular acetabular bearings made of hylamer. Journal of Arthroplasty. ,vol. 15, pp. 35- 46 ,(2000) , 10.1016/S0883-5403(00)91103-3
Paul E Beaul??, Frederick J Dorey, Michel LeDuff, Thomas Gruen, Harlan C Amstutz, Risk factors affecting outcome of metal-on-metal surface arthroplasty of the hip. Clinical Orthopaedics and Related Research. ,vol. 418, pp. 87- 93 ,(2004) , 10.1097/00003086-200401000-00015
Orhun K. Muratoglu, Charles R. Bragdon, Daniel O. O’Connor, Murali Jasty, William H. Harris, Rizwan Gul, Fred McGarry, Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE). Biomaterials. ,vol. 20, pp. 1463- 1470 ,(1999) , 10.1016/S0142-9612(99)00039-3