Nonlinearity and image persistence of P-20 phosphor-based intensified photodiode array detectors used in CARS spectroscopy

作者: D. R. Snelling , G. J. Smallwood , R. A. Sawchuk

DOI: 10.1364/AO.28.003226

关键词: Light intensityParticle detectorOpticsImage persistenceDetectorImage intensifierPhosphorPhotodiodePhotodetectorMaterials science

摘要: Several self-scanning photodiode arrays (IPDA) used for CARS spectroscopy are shown to exhibit a greater image persistence than has generally been realized, and falloff in sensitivity that is logarithmic with decreasing output signal. These effects attributed the P-20 phosphor based intensifiers IPDAs probably generic all such detectors. A strategy minimizing presented. prototype detector incorporating much faster rare earth evaluated be more suited single pulse measurements turbulent combustion phosphors.

参考文章(10)
R. K. bChang, M. B. Long, Optical Multichannel Detection lss2. ,vol. 50, pp. 179- 205 ,(1982) , 10.1007/3-540-11380-0_15
D. R. Snelling, G. J. Smallwood, T. Parameswaran, Effect of detector nonlinearity and image persistence on CARS derived temperatures. Applied Optics. ,vol. 28, pp. 3233- 3241 ,(1989) , 10.1364/AO.28.003233
L. P. Goss, D. D. Trump, B. G. MacDonald, G. L. Switzer, 10‐Hz coherent anti‐Stokes Raman spectroscopy apparatus for turbulent combustion studies Review of Scientific Instruments. ,vol. 54, pp. 563- 571 ,(1983) , 10.1063/1.1137438
D. R. Snelling, R. A. Sawchuk, G. J. Smallwood, Multichannel light detectors and their use for CARS spectroscopy. Applied Optics. ,vol. 23, pp. 4083- 4089 ,(1984) , 10.1364/AO.23.004083
D. R. Snelling, G. J. Smallwood, R. A. Sawchuk, T. Parameswaran, Precision of multiplex CARS temperatures using both single-mode and multimode pump lasers. Applied Optics. ,vol. 26, pp. 99- 110 ,(1987) , 10.1364/AO.26.000099
Richard R. Antcliff, Mervin E. Hillard, Olin Jarrett, Intensified silicon photodiode array detector linearity: application to coherent anti-Stokes Raman spectroscopy Applied Optics. ,vol. 23, pp. 2369- 2375 ,(1984) , 10.1364/AO.23.002369
S. Kr�ll, M. Ald�n, P. -E. Bengtsson, C. L�fstr�m, An evaluation of precision and systematic errors in vibrational CARS thermometry Applied Physics B. ,vol. 49, pp. 445- 453 ,(1989) , 10.1007/BF00325348
D. R. Snelling, R. A. Sawchuk, R. E. Mueller, Single pulse CARS noise: a comparison between single-mode and multimode pump lasers. Applied Optics. ,vol. 24, pp. 2771- 2778 ,(1985) , 10.1364/AO.24.002771
Yair Talmi, R. W. Simpson, Self-scanned photodiode array: a multichannel spectrometric detector Applied Optics. ,vol. 19, pp. 1401- 1414 ,(1980) , 10.1364/AO.19.001401