作者: Reiji Tanaka , Sachio Murakami , Ryoichi Fujishiro
DOI: 10.1246/BCSJ.45.2107
关键词: Calorimeter constant 、 Displacement (fluid) 、 Chemistry 、 Thermodynamics 、 Reaction calorimeter 、 Isothermal process 、 Analytical chemistry 、 Mixing (process engineering) 、 Calorimeter 、 Benzene 、 Cyclohexane 、 General chemistry
摘要: An isothermal displacement calorimeter of the Van Ness type has been constructed. The was tested on three systems, benzene+cyclohexane, cyclohexane+n-hexane, and benzene+dichloromethane, at 25°C, performance discussed in connection with literature values. precision new within 0.5%; this equal to, or better than, that calorimeters a similar which have constructed by several investigators.