Ceramic Coatings in Metal-PE Joints: Where Are We Now?

作者: C. Piconi , G. Maccauro , F. Muratori

DOI: 10.1007/978-3-7985-1968-8_19

关键词: TinTitanium alloyZirconium dioxideAlloyBearing (mechanical)CeramicMetallurgyMaterials scienceZirconium alloyTitanium nitride

摘要: Several types of hard coatings were applied onto metallic components in arthroprostheses’ bearings to reduce UHMWPE wear and the consequent debris-induced periprosthetic osteolysis, that is still main problem arthroplasty. This approach was aimed obtain surface metal finish scratch resistance similar ones alumina ceramic components. Many attempts made improve properties stainless steel, cobalt-chromium, titanium alloys zirconium alloys. Arthroprostheses’ bearing coated by nitride (TiN) or diamond-like carbon (DLC), more recently zirconium-2,5 Nb alloy with a layer monoclinic dioxide introduced on market. paper briefly reviews literature prosthetic assess today’s status this technology

参考文章(16)
L A Whiteside, S E White, D S McCarthy, M Anthony, R A Poggie, Simulated knee wear with cobalt chromium and oxidized zirconium knee femoral components. Clinical Orthopaedics and Related Research. pp. 176- 184 ,(1994)
C. Hardaker, D.C. Barton, J. Fisher, M.H. Stone, V.C. Jones, D.D. Auger, Simulation of tibial counterface wear in mobile bearing knees with uncoated and ADLC coated surfaces. Bio-medical Materials and Engineering. ,vol. 11, pp. 105- 115 ,(2001)
André Luís Paschoal, Everaldo Carlos Vanâncio, Lauralice de Campos Franceschini Canale, Orivaldo Lopes da Silva, Domingos Huerta‐Vilca, Artur de Jesus Motheo, None, Metallic biomaterials TiN-coated: corrosion analysis and biocompatibility. Artificial Organs. ,vol. 27, pp. 461- 464 ,(2003) , 10.1046/J.1525-1594.2003.07241.X
Frederick F. Buechel, Frederick F. Buechel, Michael J. Pappas, Ten-Year Evaluation of Cementless Buechel-Pappas Meniscal Bearing Total Ankle Replacement: Foot & Ankle International. ,vol. 24, pp. 462- 472 ,(2003) , 10.1177/107110070302400603
T.L. Parker, K.L. Parker, I.R. McColl, D.M. Grant, J.V. Wood, The biocompatibility of low temperature diamond-like carbon films: a transmission electron microscopy, scanning electron microscopy and cytotoxicity study Diamond and Related Materials. ,vol. 3, pp. 1120- 1123 ,(1994) , 10.1016/0925-9635(94)90104-X
Melinda K. Harman, Scott A. Banks, W.Andrew Hodge, Wear analysis of a retrieved hip implant with titanium nitride coating Journal of Arthroplasty. ,vol. 12, pp. 938- 945 ,(1997) , 10.1016/S0883-5403(97)90164-9
A. Conte, A. Borello, A. Cabrini, Anodic oxidation of zircaloy-2 Journal of Applied Electrochemistry. ,vol. 6, pp. 293- 299 ,(1976) , 10.1007/BF00608914