Neurological Monitoring During Endovascular Procedures

作者: Steven White , Richard Langford

DOI: 10.1007/978-1-4471-3659-0_8

关键词: Cerebral blood flowCerebral haemodynamicsMedicineInternal medicineOcclusionBalloon occlusionInterventional neuroradiologyNervous tissueCardiology

摘要: Interventional neuroradiology is relatively safe in most of its applications. However, there some risk producing new neurological deficits. These may result from the unintentional occlusion arterial branches to functional nervous tissue or haemorrhage, either vessel penetration during procedure itself associated with disturbances regional cerebral haemodynamics.

参考文章(83)
Seishi Jinnouchi, Katsushi Watanabe, Hiroaki Hoshi, Kazuo Kinoshita, Shinichi Nakano, Critical cerebral blood flow thresholds studied by SPECT using xenon-133 and iodine-123 iodoamphetamine. The Journal of Nuclear Medicine. ,vol. 30, pp. 337- 342 ,(1989)
C A Jungreis, J A Horton, Pressure changes in the arterial feeder to a cerebral AVM as a guide to monitoring therapeutic embolization. American Journal of Neuroradiology. ,vol. 10, pp. 1057- 1060 ,(1989)
Khalil Jawad, J. Douglas Miller, David J. Wyper, John O. Rowan, Measurement of CBF and carotid artery pressure compared with cerebral angiography in assessing collateral blood supply after carotid ligation Journal of Neurosurgery. ,vol. 46, pp. 185- 196 ,(1977) , 10.3171/JNS.1977.46.2.0185
Jonathan E. Hodes, Daniel Rufenacht, Armand Aymard, Jean Jacques Merland, Endovascular treatment of a giant fusiform aneurysm of the entire basilar artery. American Journal of Neuroradiology. ,vol. 13, pp. 1143- 1146 ,(1992)
Svante Horsch, Kiriakos Ktenidis, Intraoperative use of somatosensory evoked potentials for brain monitoring during carotid surgery. Neurosurgery Clinics of North America. ,vol. 7, pp. 693- 702 ,(1996) , 10.1016/S1042-3680(18)30354-1
John D. Barr, John M. Mathis, Joseph A. Horton, Provocative pharmacologic testing during arterial embolization. Neurosurgery Clinics of North America. ,vol. 5, pp. 403- 411 ,(1994) , 10.1016/S1042-3680(18)30508-4
G Duckwiler, J Bentson, F Vinuela, N Martin, R A Rauch, E C Amos, J Dion, S E Jordan, M E Jensen, Preembolization functional evaluation in brain arteriovenous malformations: the ability of superselective Amytal test to predict neurologic dysfunction before embolization. American Journal of Neuroradiology. ,vol. 13, pp. 309- 314 ,(1992)
Paolo Bolognese, John I. Miller, Ian M. Heger, Thomas H. Milhorat, Laser-Doppler flowmetry in neurosurgery. Journal of Neurosurgical Anesthesiology. ,vol. 5, pp. 151- 158 ,(1993) , 10.1097/00008506-199307000-00004
Z Szabo, J Chazaly, J R Schwartz, P J Jeffery, E E Camargo, B B van Heerden, L H Monsein, Assessing adequacy of collateral circulation during balloon test occlusion of the internal carotid artery with 99mTc-HMPAO SPECT American Journal of Neuroradiology. ,vol. 12, pp. 1045- 1051 ,(1991)
S B Peterman, J C Hoffman, A Taylor, Improved detection of cerebral hypoperfusion with internal carotid balloon test occlusion and 99mTc-HMPAO cerebral perfusion SPECT imaging. American Journal of Neuroradiology. ,vol. 12, pp. 1035- 1041 ,(1991)