Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure

作者: R. A. Payne , C. N. Symeonides , D. J. Webb , S. R. J. Maxwell

DOI: 10.1152/JAPPLPHYSIOL.00657.2005

关键词: Linear correlationPulse (signal processing)Internal medicinePulse Transit TimeBeat (music)HemodynamicsTransit timeBlood pressurePulse Wave Transit TimeSurgeryCardiologyMedicine

摘要: The arterial pulse-wave transit time can be measured between the ECG R-wave and finger pulse (rPTT), has been shown previously to have a linear correlation with blood pressure (BP). We hypo...

参考文章(39)
Ryoichi Ochiai, Junzo Takeda, Hidehiro Hosaka, Yoshihiro Sugo, Rie Tanaka, Takeshi Soma, The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs. Journal of Clinical Monitoring and Computing. ,vol. 15, pp. 493- 501 ,(1999) , 10.1023/A:1009950731297
A. D. HARGREAVES, A. L. MUIR, Haemodynamic responses to glyceryl trinitrate: influence of rate and duration of delivery. European Heart Journal. ,vol. 13, pp. 960- 965 ,(1992) , 10.1093/OXFORDJOURNALS.EURHEARTJ.A060300
XJ Jiang, MF O'Rourke, WQL Jin, LS Liu, CW Li, PC Tai, XC Zhang, SZ Liu, Quantification of glyceryl trinitrate effect through analysis of the synthesised ascending aortic pressure waveform Heart. ,vol. 88, pp. 143- 148 ,(2002) , 10.1136/HEART.88.2.143
Q. Li, G. G. Belz, Systolic time intervals in clinical pharmacology European Journal of Clinical Pharmacology. ,vol. 44, pp. 415- 421 ,(1993) , 10.1007/BF00315536
Brian Gribbin, Andrew Steptoe, Peter Sleight, Pulse Wave Velocity as a Measure of Blood Pressure Change Psychophysiology. ,vol. 13, pp. 86- 90 ,(1976) , 10.1111/J.1469-8986.1976.TB03344.X
Andrew Steptoe, Harold Smulyan, Brian Gribbin, Pulse Wave Velocity and Blood Pressure Change: Calibration and Applications Psychophysiology. ,vol. 13, pp. 488- 493 ,(1976) , 10.1111/J.1469-8986.1976.TB00866.X
Ian B Wilkinson, Helen MacCallum, Patrick C Hupperetz, Caspar J Van Thoor, John R Cockcroft, David J Webb, None, Changes in the derived central pressure waveform and pulse pressure in response to angiotensin II and noradrenaline in man The Journal of Physiology. ,vol. 530, pp. 541- 550 ,(2001) , 10.1111/J.1469-7793.2001.0541K.X
Stavros Loukogeorgakis, Rex Dawson, Nirree Phillips, Christopher N Martyn, Stephen E Greenwald, Validation of a device to measure arterial pulse wave velocity by a photoplethysmographic method Physiological Measurement. ,vol. 23, pp. 581- 596 ,(2002) , 10.1088/0967-3334/23/3/309