作者: Murad A. Rahim
DOI: 10.1061/(ASCE)EY.1943-7897.0000127
关键词: Combustion chamber 、 Environmental engineering 、 Exergy 、 Natural gas 、 Heat recovery steam generator 、 Engineering 、 Energy recovery 、 Combined cycle 、 Power station 、 Exergy efficiency
摘要: AbstractIn this study, energy and exergy evaluation parametric study were carried out using the actual operating parameters of a combined cycle power plant 52 MW having dual pressure heat recovery steam generator (HRSG) natural gas as fuel located in Ankara city. The objective is to investigate flow main units well losses. Also, present investigates effect site conditions (ambient temperature, altitude) on based first second laws thermodynamics. results show that combustion chambers HRSGs are sources irreversibilities, accounting for 89% overall total loss efficiency determined be 68.599 MW 40.66%, respectively.