Point-of-Care 3D Printing: A Feasibility Study of Using 3D Printing for Orthopaedic Trauma.

作者: Alex Quok An Teo , David Qing Kai Ng , Gavin Kane O'neill , Peng Lee

DOI: 10.1016/J.INJURY.2021.02.041

关键词: Orthopaedic traumaPoint of careFixation (surgical)Lateral tibial plateau3D printingImplantMedicineOrthodonticsSurgical drillCadaveric spasm

摘要: … The aim of this study was to assess the feasibility of 3D printing a customised implant at the point of care from a manufacturing and logistics perspective. We hypothesised that …

参考文章(39)
M. Ahmad, R. Nanda, A.S. Bajwa, J. Candal-Couto, S. Green, A.C. Hui, Biomechanical testing of the locking compression plate: When does the distance between bone and implant significantly reduce construct stability? Injury-international Journal of The Care of The Injured. ,vol. 38, pp. 358- 364 ,(2007) , 10.1016/J.INJURY.2006.08.058
Joseph Borrelli, Management of soft tissue injuries associated with tibial plateau fractures. Journal of Knee Surgery. ,vol. 27, pp. 5- 9 ,(2013) , 10.1055/S-0033-1363546
Nina Kozic, Stefan Weber, Philippe Büchler, Christian Lutz, Nils Reimers, Miguel Á. González Ballester, Mauricio Reyes, Optimisation of orthopaedic implant design using statistical shape space analysis based on level sets Medical Image Analysis. ,vol. 14, pp. 265- 275 ,(2010) , 10.1016/J.MEDIA.2010.02.008
Eduardo M. Suero, Tobias Hüfner, Timo Stübig, Christian Krettek, Musa Citak, Use of a virtual 3D software for planning of tibial plateau fracture reconstruction. Injury-international Journal of The Care of The Injured. ,vol. 41, pp. 589- 591 ,(2010) , 10.1016/J.INJURY.2009.10.053
Thuc-Quyen D. Nguyen, Andrew Y. Park, James Guido DiStefano, Jenni M. Buckley, William H. Montgomery, Christopher D. Grimsrud, Congruency of Scapula Locking Plates: Implications for Implant Design ASME 2010 Summer Bioengineering Conference, Parts A and B. pp. 501- 502 ,(2010) , 10.1115/SBC2010-19117
Ariel A Williams, Daniela M Witten, Rosanna Duester, Loretta B Chou, The benefits of implant removal from the foot and ankle. Journal of Bone and Joint Surgery, American Volume. ,vol. 94, pp. 1316- 1320 ,(2012) , 10.2106/JBJS.J.01756
Kanu S Goyal, Anthony S Skalak, Randall E Marcus, Heather A Vallier, Daniel R Cooperman, Analysis of anatomic periarticular tibial plate fit on normal adults. Clinical Orthopaedics and Related Research. ,vol. 461, pp. 245- 257 ,(2007) , 10.1097/BLO.0B013E31809E6E45
Liciane Sabadin Bertol, Wilson Kindlein Júnior, Fabio Pinto da Silva, Claus Aumund-Kopp, Medical design: Direct metal laser sintering of Ti–6Al–4V Materials & Design. ,vol. 31, pp. 3982- 3988 ,(2010) , 10.1016/J.MATDES.2010.02.050
M.W Khaing, J.Y.H Fuh, L Lu, Direct metal laser sintering for rapid tooling: processing and characterisation of EOS parts Journal of Materials Processing Technology. ,vol. 113, pp. 269- 272 ,(2001) , 10.1016/S0924-0136(01)00584-2
Trenton W. Holliday, Christopher B. Ruff, Relative variation in human proximal and distal limb segment lengths American Journal of Physical Anthropology. ,vol. 116, pp. 26- 33 ,(2001) , 10.1002/AJPA.1098