Thermal analysis and post construction verification

作者: Cormac Flood , Lloyd Scott

DOI: 10.1108/IJBPA-12-2018-0098

关键词: Energy performanceThermal transmittanceResidential sectorEnergy demandFossil fuelThermal analysisCivil engineeringEnvironmental scienceUpgradeCalculation methods

摘要: Purpose The residential sector in Ireland accounted for 25 per cent of energy related CO2 emissions in 2016 through burning fossil fuels, a major contributor to climate change. In support of Ireland’s CO2 reduction targets, the existing housing stock could contribute greatly to the reduction of space-heating energy demand through retrofit. Approximately 50 per cent of Ireland’s 2m dwellings pre-date building regulations and are predominantly of cavity and solid wall construction, the performance of which has not been extensively investigated at present. Although commitment to thermal upgrade/retrofit of existing buildings may increase under future government policies, the poor characterisation of actual thermal performance of external walls may hinder the realisation of these targets. Thermal transmittance (U-values) of exterior walls represents a source of uncertainty when estimating the energy performance of dwellings. It has been noted in research that the standard calculation methodology for thermal transmittance should be improved. Implementing current U-value calculation methods may result in misguided retrofit strategies due to the considerable discrepancies between in situ measurements and calculated wall U-values as documented in the case studies carried out in this research. If the method of hygrothermal analysis were to be employed as a replacement for the current standard calculation, it could have significant implications for policy and retrofit decision making. The paper aims to discuss this issue. Design/methodology/approach This research project analysed a case study situated in Dublin, Ireland. The case studies offer an account of the in situ thermal transmittance of exterior walls and link these to hygrothermally simulated comparisons along with more traditional design U-values. Findings The findings of this research identify discrepancies between in situ and design U-values, using measurement, hygrothermal simulation and standard method U-value calculations. The outcomes of the research serve as an introduction to issues emanating from a larger research project in order to encourage researchers to understand and further explore the topic. Originality/value It has previously been highlighted that moisture content is linked to the increase in thermal conductivity of building materials, thus reducing the thermal effectiveness and increasing the elemental U-value. Therefore, it is vital to implement reliable prediction tools to assess potential thermal performance values. This paper presents the findings of a critical instance case study in Dublin, Ireland in which an existing west facing external wall in a semi-detached dwelling was analysed, simulated and measured to verify the elemental wall assembly and quantify thermal transmittance (U-value) incorporating the major criteria required for building performance simulation.

参考文章(17)
John Currie, Julio Bros Williamson, Jon Stinson, Historic Scotland Technical Paper 19 - Monitoring thermal upgrades to ten traditional properties Historic Scotland. ,(2013)
Luca Evangelisti, Claudia Guattari, Paola Gori, Roberto Vollaro, In Situ Thermal Transmittance Measurements for Investigating Differences between Wall Models and Actual Building Performance Sustainability. ,vol. 7, pp. 10388- 10398 ,(2015) , 10.3390/SU70810388
Eshrar Latif, Simon Tucker, Mihaela Anca Ciupala, Devapriya Chitral Wijeyesekera, Darryl John Newport, Marian Pruteanu, None, Quasi steady state and dynamic hygrothermal performance of fibrous Hemp and Stone Wool insulations: Two innovative laboratory based investigations Building and Environment. ,vol. 95, pp. 391- 404 ,(2016) , 10.1016/J.BUILDENV.2015.10.006
Francesco Asdrubali, Francesco D’Alessandro, Giorgio Baldinelli, Francesco Bianchi, Evaluating in situ thermal transmittance of green buildings masonries—A case study Case Studies in Construction Materials. ,vol. 1, pp. 53- 59 ,(2014) , 10.1016/J.CSCM.2014.04.004
Changhai Peng, Zhishen Wu, In situ measuring and evaluating the thermal resistance of building construction Energy and Buildings. ,vol. 40, pp. 2076- 2082 ,(2008) , 10.1016/J.ENBUILD.2008.05.012
H.M. Künzel, A. Holm, D. Zirkelbach, A.N. Karagiozis, Simulation of indoor temperature and humidity conditions including hygrothermal interactions with the building envelope Solar Energy. ,vol. 78, pp. 554- 561 ,(2005) , 10.1016/J.SOLENER.2004.03.002
Aimee Byrne, Gerard Byrne, Anna Davies, Anthony James Robinson, Transient and quasi-steady thermal behaviour of a building envelope due to retrofitted cavity wall and ceiling insulation Energy and Buildings. ,vol. 61, pp. 356- 365 ,(2013) , 10.1016/J.ENBUILD.2013.02.044
Christopher Gorse, Guest Editorial: The sustainability challenge: measurement to reduce global emissions Construction Innovation: Information, Process, Management. ,vol. 16, pp. 2- 10 ,(2016) , 10.1108/CI-07-2015-0041