作者: Mario Ponce-Silva , Juan Aqui , Victor Olivares-Peregrino , Marco Oliver-Salazar
DOI: 10.1109/TPEL.2016.2520925
关键词: Resonant inverter 、 Maximum power point tracking 、 Switched-mode power supply 、 Electrical engineering 、 Electrical efficiency 、 Engineering 、 Power factor 、 AC power 、 Rectifier 、 Inverter
摘要: The arrangement of the full-bridge, current-source inverter as a power supply for ozone generators providing high factor (PF) and electrical efficiency in single stage is main contribution this paper. corresponding design, simulation, experimental results are presented. Also, use current-fed, full-bridge resonant PF correction generation applications discussed. proposed consists an ac supply, rectifier bridge, input inductor to inverter, four switches, LC parallel tank, transformer, set generating cells. Experimental with topology provided 96% PF, 91% efficiency, production 614 mgO3/min, satisfying requirements standard 61000-3-2, class A.