Intra-aortic Balloon Pumping and Other Circulatory Assist Devices

作者: Carol L. Lake

DOI: 10.1007/978-1-4612-5048-7_14

关键词: Intra-Aortic Balloon PumpingIntraaortic balloon pumpBalloonCirculatory systemIntraaortic balloonInternal medicineMedicineCardiologyBlood pressureHeart failureCardiogenic shock

摘要: In the past two decades, there has been significant progress in development of devices to assist circulation patients with heart failure. The concept counterpulsation was first reported 1961 (18). Counterpulsation an intra-aortic balloon, rather than withdrawal and reinjection blood, proved be effective method increasing aortic diastolic pressure is now widespread use. An implantable chronic device 1966 (39), but these remain experimental stages have limited

参考文章(88)
D. A. Holub, C. W. Hibbs, J. T. Sturm, J. M. Fuqua, C. H. Edmonds, M. G. McGee, T. M. Fuhrman, R. Trono, S. R. Igo, J. C. Norman, CLINICAL TRIALS OF THE ABDOMINAL LEFT VENTRICULAR ASSIST DEVICE (ALVAD): PROGRESS REPORT. Cardiovascular diseases. ,vol. 6, pp. 359- 372 ,(1979) , 10.1097/00002480-197902500-00037
Michael G. McGee, Sherri L. Zillgitt, Ruben Trono, Stephen A. Turner, Gary L. Davis, John M. Fuqua, Sidney K. Edelman, John C. Norman, Retrospective analyses of the need for mechanical circulatory support (intraaortic balloon pump/abdominal left ventricular assist device or partial artificial heart) after cardiopulmonary bypass American Journal of Cardiology. ,vol. 46, pp. 135- 142 ,(1980) , 10.1016/0002-9149(80)90615-3
Steven Wolfson, Dennis L. Karsh, Rene A. Langou, Alexander S. Geha, Graeme L. Hammond, Lawrence S. Cohen, Modification of intraaortic balloon catheter to permit introduction by cardiac catheterization techniques. American Journal of Cardiology. ,vol. 41, pp. 733- 738 ,(1978) , 10.1016/0002-9149(78)90825-1
David Bregman, Percutaneous Intra-aortic Balloon Pumping Chest. ,vol. 82, pp. 397- 398 ,(1982) , 10.1378/CHEST.82.4.397
R C Leinbach, H K Gold, R W Harper, M J Buckley, W G Austen, Early intraaortic balloon pumping for anterior myocardial infarction without shock. Circulation. ,vol. 58, pp. 204- 210 ,(1978) , 10.1161/01.CIR.58.2.204
Joseph Alpert, Vascular Complications of Intra-aortic Balloon Pumping Archives of Surgery. ,vol. 111, pp. 1190- 1195 ,(1976) , 10.1001/ARCHSURG.1976.01360290024004
Robert C. Leinbach, Emery Nyilas, James B. Caulfield, Mortimer J. Buckley, W. Gerald Austen, Evaluation of hematologic effects of intra-aortic balloon assistance in man. Asaio Journal. ,vol. 18, pp. 493- 500 ,(1972) , 10.1097/00002480-197201000-00119
Ercument A. Kopman, Rebecca C. Ramirez-Inawat, Intra-aortic balloon counterpulsation for right heart failure. Anesthesia & Analgesia. ,vol. 59, pp. 74- ,(1980) , 10.1213/00000539-198001000-00018
David Bregman, William J. Casarella, Percutaneous Intraaortic Balloon Pumping: Initial Clinical Experience The Annals of Thoracic Surgery. ,vol. 29, pp. 153- 155 ,(1980) , 10.1016/S0003-4975(10)61654-2