Two-dimensional versus three-dimensional CT scan for aortic measurement.

作者: Ellen D. Dillavou , David G. Buck , Satish C. Muluk , Michel S. Makaroun

DOI: 10.1177/152660280301000319

关键词: Three dimensional ctPerpendicularAbdominal aortic aneurysmBlood flowMedicineTomographyNuclear medicineAortic aneurysm3D reconstructionAccuracy and precision

摘要: Purpose:To examine if 3-dimensional (3D) reconstructions of computed tomographic (CT) data, by imaging perpendicular to blood flow, can improve aortic diameter measurement accuracy over axial (2D) ...

参考文章(26)
Frank A. Lederle, Samuel E. Wilson, Gary R. Johnson, Fred N. Littooy, Charles Acher, Louis M. Messina, Donovan B. Reinke, David J. Ballard, Design of the abdominal aortic Aneurysm Detection and Management Study Journal of Vascular Surgery. ,vol. 20, pp. 296- 303 ,(1994) , 10.1016/0741-5214(94)90019-1
Takuya Hatakeyama, Hiroshi Shigematsu, Tetsuichiro Muto, Risk factors for rupture of abdominal aortic aneurysm based on three-dimensional study Journal of Vascular Surgery. ,vol. 33, pp. 453- 461 ,(2001) , 10.1067/MVA.2001.111731
Jon S Matsumura, Barry T Katzen, Larry H Hollier, Michael D Dake, Update on the bifurcated EXCLUDER endoprosthesis: phase I results Journal of Vascular Surgery. ,vol. 33, pp. 150- 153 ,(2001) , 10.1067/MVA.2001.111685
Frank J. Criado, Eric P. Wilson, Ronald M. Fairman, Omran Abul-Khoudoud, Eric Wellons, Update on the Talent aortic stent-graft: a preliminary report from United States phase I and II trials. Journal of Vascular Surgery. ,vol. 33, pp. 146- 149 ,(2001) , 10.1067/MVA.2001.111677
Robert Y. Rhee, Mark K. Eskandari, Albert B. Zajko, Michel S. Makaroun, Long-term fate of the aneurysmal sac after endoluminal exclusion of abdominal aortic aneurysms Journal of Vascular Surgery. ,vol. 32, pp. 689- 696 ,(2000) , 10.1067/MVA.2000.110172
Rodney A. White, Carlos E. Donayre, Irwin Walot, Jonathan Woody, Namil Kim, George E. Kopchok, Computed tomography assessment of abdominal aortic aneurysm morphology after endograft exclusion. Journal of Vascular Surgery. ,vol. 33, pp. 1- 10 ,(2001) , 10.1067/MVA.2001.111680
J. Martin Bland, DouglasG. Altman, Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet. ,vol. 327, pp. 307- 310 ,(1986) , 10.1016/S0140-6736(86)90837-8
Manfred Tillich, Bradley B. Hill, David S. Paik, Kerstin Petz, Sandy Napel, Christopher K. Zarins, Geoffrey D. Rubin, Prediction of aortoiliac stent-graft length: comparison of measurement methods. Radiology. ,vol. 220, pp. 475- 483 ,(2001) , 10.1148/RADIOLOGY.220.2.R01AU21475
LORI B. LERNER, HORACE F. HENRIQUES, ROBERT D. HARRIS, INTERACTIVE 3-DIMENSIONAL COMPUTERIZED TOMOGRAPHY RECONSTRUCTION IN EVALUATION OF THE LIVING RENAL DONOR The Journal of Urology. ,vol. 161, pp. 403- 407 ,(1999) , 10.1016/S0022-5347(01)61902-5