Effects of incorporation of HA/ZrO2 into glass ionomer cement (GIC)

作者: Y.W. Gu , A.U.J. Yap , P. Cheang , K.A. Khor

DOI: 10.1016/J.BIOMATERIALS.2004.03.019

关键词: Compressive strengthIndentation hardnessCubic zirconiaComposite numberUltimate tensile strengthMaterials scienceDistilled waterCrystallinityComposite materialGlass ionomer cement

摘要: Glass ionomer cements (GICs) are a class of bioactive cements that bond directly to bone. In this paper, a new bioactive hydroxyapatite (HA)/zirconia (ZrO 2 )-filled GIC composite was …

参考文章(23)
Viviane V. Silva, Fernando S. Lameiras, Z�lia I. P. Lobato, Biological reactivity of zirconia–hydroxyapatite composites Journal of Biomedical Materials Research. ,vol. 63, pp. 583- 590 ,(2002) , 10.1002/JBM.10308
L.M. Jonck, C.J. Grobbelaar, H. Strating, The biocompatibility of glass-ionomer cement in joint replacement: Bulk testing Clinical Materials. ,vol. 4, pp. 85- 107 ,(1989) , 10.1016/0267-6605(89)90001-2
John W. Nicholson, Chemistry of glass-ionomer cements: a review. Biomaterials. ,vol. 19, pp. 485- 494 ,(1998) , 10.1016/S0142-9612(97)00128-2
J. W. Nicholson, S. J. Hawkins, J. E. Smith, The incorporation of hydroxyapatite into glass-polyalkenoate (“glass-ionomer”) cements: a preliminary study Journal of Materials Science: Materials in Medicine. ,vol. 4, pp. 418- 421 ,(1993) , 10.1007/BF00122202
Erik O. Martz, Vijay K. Goel, Malcolm H. Pope, Joon B. Park, Materials and design of spinal implants—A review Journal of Biomedical Materials Research. ,vol. 38, pp. 267- 288 ,(1997) , 10.1002/(SICI)1097-4636(199723)38:3<267::AID-JBM12>3.0.CO;2-8
H.H.K Xu, F.C Eichmiller, J.M Antonucci, G.E Schumacher, L.K Ives, Dental resin composites containing ceramic whiskers and precured glass ionomer particles. Dental Materials. ,vol. 16, pp. 356- 363 ,(2000) , 10.1016/S0109-5641(00)00028-2
Michael J. Heffernan, Steven A. Aquilino, Ana M. Diaz-Arnold, Debra R. Haselton, Clark M. Stanford, Marcos A. Vargas, Relative translucency of six all-ceramic systems. Part I: Core materials Journal of Prosthetic Dentistry. ,vol. 88, pp. 4- 9 ,(2002) , 10.1067/MPR.2002.126794
T. Kasuga, M. Yoshida, A. J. Ikushima, M. Tuchiya, H. Kusakari, Stability of zirconia-toughened bioactive glass-ceramics: in vivo study using dogs Journal of Materials Science: Materials in Medicine. ,vol. 4, pp. 36- 39 ,(1993) , 10.1007/BF00122975
A. D. Wilson, Secondary reactions in glass-ionomer cements Journal of Materials Science Letters. ,vol. 15, pp. 275- 276 ,(1996) , 10.1007/BF00274473
A D Wilson, B E Kent, A new translucent cement for dentistry. The glass ionomer cement British Dental Journal. ,vol. 132, pp. 133- 135 ,(1972) , 10.1038/SJ.BDJ.4802810