TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region

作者: Petr Hubka , Ondrej Nanka , Jaromir Masata , Alois Martan , Kamil Svabik

DOI: 10.1007/S00192-015-2922-3

关键词: Fixation (histology)ForamenMedicineCadaveric spasmGynecologic surgical proceduresSuburethral SlingPosition (obstetrics)Anatomy

摘要: Introduction and hypothesis The aim of the study was to describe fixation TVT ABBREVO establish whether tape penetrates through obturator muscles membrane (obturator complex) into adductor region and, if so, how far it penetrates.

参考文章(17)
Virginie Canel, Thibault Thubert, Ingrid Wigniolle, Hervé Fernandez, Xavier Deffieux, Postoperative groin pain and success rates following transobturator midurethral sling placement: TVT ABBREVO® system versus TVT™ obturator system International Urogynecology Journal. ,vol. 26, pp. 1509- 1516 ,(2015) , 10.1007/S00192-015-2723-8
Jonathan S. Shaw, Peter C. Jeppson, Charles R. Rardin, Decreasing transobturator sling groin pain without decreasing efficacy using TVT-Abbrevo. International Urogynecology Journal. ,vol. 26, pp. 1369- 1372 ,(2015) , 10.1007/S00192-015-2718-5
Abigail A Ford, Lynne Rogerson, June D Cody, Patricia Aluko, Joseph A Ogah, Mid-urethral sling operations for stress urinary incontinence in women. Cochrane Database of Systematic Reviews. ,vol. 7, pp. 0- 0 ,(2017) , 10.1002/14651858.CD006375.PUB4
Petr Hubka, Stergios K. Doumouchtsis, Mitchell B. Berger, John O. DeLancey, Variation of distances from mid-urethra to the obturator foramen: an MRI study International Urogynecology Journal. ,vol. 23, pp. 1075- 1080 ,(2012) , 10.1007/S00192-012-1735-X
Piet Hinoul, Pierre Bonnet, Ladislav Krofta, David Waltregny, Jean de Leval, An anatomic comparison of the original versus a modified inside-out transobturator procedure International Urogynecology Journal. ,vol. 22, pp. 997- 1004 ,(2011) , 10.1007/S00192-011-1415-2
Jean-Nicolas Cornu, Philippe Sèbe, Laurence Peyrat, Calin Ciofu, Olivier Cussenot, Francois Haab, Midterm prospective evaluation of TVT-Secur reveals high failure rate. European Urology. ,vol. 58, pp. 157- 161 ,(2010) , 10.1016/J.EURURO.2010.04.021
Petr Hubka, Ondrej Nanka, Alois Martan, Kamil Svabik, Jana Zvarova, Jaromir Masata, Anatomical study of position of the TVT-O to the obturator nerve influenced by the position of the legs during the procedure: based upon findings at formalin-embalmed and fresh-frozen bodies Archives of Gynecology and Obstetrics. ,vol. 284, pp. 901- 905 ,(2011) , 10.1007/S00404-010-1775-8
Petr Hubka, Jaromir Masata, Ondrej Nanka, Milos Grim, Alois Martan, Jana Zvarova, Anatomical relationship and fixation of tension-free vaginal tape Secur International Urogynecology Journal. ,vol. 20, pp. 681- 688 ,(2009) , 10.1007/S00192-009-0815-Z