Monitoring in Acute Brain Injury

作者: E. G. McKeating

DOI: 10.1007/978-88-470-2099-3_2

关键词: Intensive care medicineCerebral perfusion pressureRespiratory systemJugular bulbIntensive care unitMedicine

摘要: Advances in technology have provided us with an array of monitors that may be used the intensive care unit (ICU) to monitor patients acute brain injury (Fig. 1). It is, however, particularly important when considering this topic, remember will not function without support other body systems, e.g., cardiovascular and respiratory systems. Proper discussion must therefore start basic principles management monitoring acutely ill patient.

参考文章(35)
S. S. Koura, E. M. R. Doppenberg, Anthony Marmarou, S. Choi, H. F. Young, R. Bullock, Relationship between excitatory amino acid release and outcome after severe human head injury. Acta Neurochirurgica. ,vol. 71, pp. 244- 246 ,(1998) , 10.1007/978-3-7091-6475-4_70
Ian Piper, , L. Dunn, C. Contant, Y. Yau, I. Whittle, G. Citerio, K. Kiening, W. Schvning, S. Ng, W. Poon, P. Enblad, P. Nilsson, Multi-centre assessment of the Spiegelberg compliance monitor: preliminary results. Acta Neurochirurgica. ,vol. 76, pp. 491- 494 ,(2000) , 10.1007/978-3-7091-6346-7_103
Sandra Rossi, F. Buzzi, A. Paparella, P. Mainini, N. Stocchetti, Complications and Safety Associated with ICP Monitoring: A Study of 542 Patients Acta Neurochirurgica. ,vol. 71, pp. 91- 93 ,(1998) , 10.1007/978-3-7091-6475-4_28
R M Chesnut, Secondary brain insults after head injury: clinical perspectives. New horizons (Baltimore, Md.). ,vol. 3, pp. 366- 375 ,(1995)
R. Reisch, D. Mauer, R. Filippi, A. Perneczky, Brain tissue pO2 related to SjvO2, ICP, and CPP in severe brain injury Neurosurgical Review. ,vol. 23, pp. 94- 97 ,(2000) , 10.1007/PL00021700
Seymour S. Kety, Study of the cerebral circulation by means of inert diffusible tracers. Progress in Brain Research. ,vol. 35, pp. 375- 385 ,(1972) , 10.1016/S0079-6123(08)60100-4
P.S. SEBEL, D.E. MAYNARD, E. MAJOR, M. FRANK, THE CEREBRAL FUNCTION ANALYSING MONITOR (CFAM) A new microprocessor-based device for the on-line analysis of the EEG and evoked potentials BJA: British Journal of Anaesthesia. ,vol. 55, pp. 1265- 1270 ,(1983) , 10.1093/BJA/55.12.1265
MICHAEL J. ROSNER, SHEILA DAUGHTON, Cerebral perfusion pressure management in head injury. Journal of Trauma-injury Infection and Critical Care. ,vol. 30, pp. 933- 941 ,(1990) , 10.1097/00005373-199008000-00001
Kwan-Hon Chan, N. Mark Dearden, J. Douglas Miller, Peter J. D. Andrews, Susan Midgley, Multimodality Monitoring as a Guide to Treatment of Intracranial Hypertension after Severe Brain Injury Neurosurgery. ,vol. 32, pp. 547- 553 ,(1993) , 10.1227/00006123-199304000-00009