作者: R. Sainsbury , N. L. Gilchrist , M. E. J. Beard , H. C. Hanger
DOI:
关键词: Physiology 、 Erythrocyte sedimentation 、 Erythrocyte sedimentation rate 、 Reference range 、 Reference standards 、 Medicine 、 Cross-sectional study
摘要: One hundred and ninety-four elderly subjects living in the community were randomly selected order to define a reference range for erythrocyte sedimentation rate (ESR) this age group. Mean (S.D) values 4.1 (2.9) mm one hour 7.2 (2.6) men women respectively. Values ranged from 0-44 hour. The ESR showed significant independent correlations with fibrinogen, haemoglobin (male female) albumin levels only). A new algorithm determination of upper limit normal is proposed: Females = Age/3 + 10 Male Age/3.