Capillary injection device for in situ pre-concentration of trace elements in graphite furnace-atomic absorption spectrometry

作者: Alessio Ceccarini , Roger Fuoco , Carolina Vecchio

DOI: 10.1016/S0584-8547(01)00307-X

关键词: Absorption (electromagnetic radiation)Detection limitMass spectrometryChromatographyChemistryYield (chemistry)GraphiteDeposition (phase transition)Analytical chemistryStandard solutionGraphite furnace atomic absorption

摘要: Abstract A device for in situ pre-concentration of trace elements graphite furnace-atomic absorption spectrometry (GF-AAS), which is based on the direct introduction sample solution into furnace by a fused silica capillary, described. Experimental conditions have been optimized determination several at sub pg/g level with CV always better than 15%. deposition yield approximately 95% was estimated depositing containing NaCl 0.002 M. very simple and effective handling under contamination-free also described allowed less 10% to be obtained replicate determinations Cd blank samples 0.4 pg/g. The overall analytical system validated recovery studies carried out standard solutions spiked snow samples. Measurements were performed 1, 5 50 pg/g, error lower 20, 10 5%, respectively. evaluation experimental detection limits ranged interval 0.1–4 finally discussed.

参考文章(16)
M. A. Bolshov, V. Koloshnikov, C. Boutron, C. Patterson, N. Barkov, Determination of Toxic Metals in Environmental Objects by Laser Excited Atomic Fluorescence Spectrometry Springer US. pp. 185- 197 ,(1990) , 10.1007/978-1-4684-5895-4_16
Carlo Barbante, Giulio Cozzi, Gabriele Capodaglio, Katja Van de Velde, Christophe Ferrari, Audrey Veysseyre, Claude F. Boutron, Giuseppe Scarponi, Paolo Cescon, Determination of Rh, Pd, and Pt in polar and Alpine snow and ice by double-focusing ICPMS with microconcentric nebulization Analytical Chemistry. ,vol. 71, pp. 4125- 4133 ,(1999) , 10.1021/AC981437G
J Matousek, Aerosol deposition in furnace atomization Talanta. ,vol. 24, pp. 315- 319 ,(1977) , 10.1016/0039-9140(77)80008-8
Jean-François Alary, Eric D. Salin, Rapid sample preconcentration by spray deposition for electrothermal vaporization inductively coupled plasma spectrometry Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 50, pp. 405- 413 ,(1995) , 10.1016/0584-8547(94)00133-G
G.R. Dulude, J.J. Sotera, Dealing with interferences in furnace atomizer AAS—Se in nickel alloys Spectrochimica Acta Part B: Atomic Spectroscopy. ,vol. 39, pp. 511- 518 ,(1984) , 10.1016/0584-8547(84)80058-0
Carlo Barbante, Giulio Cozzi, Gabriele Capodaglio, Katja van de Velde, Christophe Ferrari, Claude Boutron, Paolo Cescon, Trace element determination in alpine snow and ice by double focusing inductively coupled plasma mass spectrometry with microconcentric nebulization Journal of Analytical Atomic Spectrometry. ,vol. 14, pp. 1433- 1438 ,(1999) , 10.1039/A901949I
J. J. Sotera, L. C. Cristiano, M. K. Conley, H. L. Kahn, Reduction of matrix interferences in furnace atomic absorption spectrometry Analytical Chemistry. ,vol. 55, pp. 204- 208 ,(1983) , 10.1021/AC00253A009
J.G. Shabushnig, G.M. Hieftje, Microdrop sample application in electrothermal atomization for atomic absorption spectrometry Analytica Chimica Acta. ,vol. 148, pp. 181- 192 ,(1983) , 10.1016/S0003-2670(00)85163-6