Measurements of harmonic emission versus active power from wind turbines

作者: Kai Yang , Math H.J. Bollen , E.O. Anders Larsson , Mats Wahlberg

DOI: 10.1016/J.EPSR.2013.11.025

关键词: HarmonicEngineeringElectromagnetic compatibilityElectronic engineeringWind powerAcousticsHarmonicsPower factorAC powerPower (physics)Harmonic analysis

摘要: This paper presents harmonic measurements from three individual wind turbines (2 and 2.5MW size). Both harmonics interharmonics have been evaluated, especially with reference to variations in the active-power production. The overall spectra reveal that, emission components may occur at any frequency not only odd harmonics. Interharmonics even emitted are relatively high. Individual depend on power production dierent ways: characteristic independent of power; show a strong correlation other interharmonic present various patterns. It is concluded that factor determining current energy conversion system.

参考文章(18)
Irene Yu-Hua Gu, Math H. J. Bollen, Signal processing of power quality disturbances ,(2006)
Jos Arrillaga, Neville R. Watson, Power System Harmonics ,(1985)
J. Arrillaga, Neville R Watson, S Chen, Power System Quality Assessment ,(2000)
Sarah Rönnberg, Math Bollen, Anders Larsson, Jean-Luc Schanen, A simple model for interaction between equipment at a frequency of some tens of kHz Proceedings of CIRED 21st International Conference on Electricity Distribution. ,(2011)
Angelo Baggini, Zbigniew Hanzelka, Voltage and Current Harmonics John Wiley & Sons, Ltd. pp. 187- 261 ,(2008) , 10.1002/9780470754245.CH7
Ned Mohan, William P. Robbins, Tore M. Undeland, Power Electronics: Converters, Applications and Design ,(1989)
Navid Zargari, Samir Kouro, Bin Wu, Yongqiang Lang, Power Conversion and Control of Wind Energy Systems ,(2011)
Roger C Dugan, Mark F McGranaghan, Surya Santoso, H Wayne Beaty, Electrical Power Systems Quality ,(1995)