Effect of particle electrostatic charge on aerosol filtration by a fibrous filter

作者: M.V. Rodrigues , M.A.S. Barrozo , J.A.S. Gonçalves , J.R. Coury

DOI: 10.1016/J.POWTEC.2017.03.033

关键词: FiltrationElectric chargePressure dropParticleAnalytical chemistryElectrophoresisAerosolCharge (physics)Venturi effectMaterials science

摘要: Abstract This study aimed to investigate the influence of particle charge level on collection efficiency and pressure drop during aerosol filtration in a fiber filter. An Electrostatic Charge Classifier (ECC) measured as function diameter. The filter was made polypropylene; its mass per area 600 g/m2, diameter 0.047 m, thickness 0.0026 m. Phosphate rock test dust (density: 3030 kg/m3; average Stokes diameter: 3.25 μm). dispersed air by TSI Venturi type generator, model SSPD 3433. charging achieved corona charger. A relationship between particles their identified. From results, it analyzed effect electrostatic charges performance (collection drop). correlations from literature did not adequately predict experimental data behaviour. Thus, we proposed new expression for electrophoretic mechanism, which consistent with results found this research, well other studies literature.

参考文章(30)
Robert C. Ph.D. Weast, Handbook of Chemistry and Physics ,(1970)
D. A. Lundgren, K. T. Whitby, Effect of Particle Electrostatic Charge on Filtration by Fibrous Filters Industrial & Engineering Chemistry Process Design and Development. ,vol. 4, pp. 345- 349 ,(1965) , 10.1021/I260016A001
Oswaldo B. Duarte Fo., Wiclef D. Marra, George C. Kachan, José R. Coury, Filtration of Electrified Solid Particles Industrial & Engineering Chemistry Research. ,vol. 39, pp. 3884- 3895 ,(2000) , 10.1021/IE0002430
R. Gougeon, D. Boulaud, A. Renoux, 15.P.01 Theoretical and experimental study of fibrous filters loading with liquid aerosols in the inertial regime Journal of Aerosol Science. ,vol. 25, pp. 189- 190 ,(1994) , 10.1016/0021-8502(94)90325-5
Sheng-Hsiu Huang, Chun-Wan Chen, Cheng-Ping Chang, Chane-Yu Lai, Chih-Chieh Chen, Penetration of 4.5nm to aerosol particles through fibrous filters Journal of Aerosol Science. ,vol. 38, pp. 719- 727 ,(2007) , 10.1016/J.JAEROSCI.2007.05.007
Luiz GM Vieira, João JR Damasceno, Marcos AS Barrozo, None, Improvement of hydrocyclone separation performance by incorporating a conical filtering wall Chemical Engineering and Processing. ,vol. 49, pp. 460- 467 ,(2010) , 10.1016/J.CEP.2010.03.011
YASUSHIGE MORI, TOSHIYA SHIOMI, NAOKI KATADA, HIROSHI MINAMIDE, KOICHI IINOYA, Effects of corona precharger on performance of fabric filter. Journal of Chemical Engineering of Japan. ,vol. 15, pp. 211- 216 ,(1982) , 10.1252/JCEJ.15.211
W.D. Marra Jr., J.R. Coury, Measurement of the electrostatic charge in airborne particles: I - development of the equipment and preliminary results Brazilian Journal of Chemical Engineering. ,vol. 17, pp. 39- 50 ,(2000) , 10.1590/S0104-66322000000100004