Extracorporeal Endotoxin Removal For The Treatment of Sepsis:Endotoxin Adsorption Cartridge (Toraymyxin)

作者: Hisataka Shoji

DOI: 10.1046/J.1526-0968.2003.00005.X

关键词: Systemic inflammatory response syndromeExtracorporealAnesthesiaSepsisHemodynamicsMedicineSeptic shockPolymyxin BNational health insuranceEndotoxin removal

摘要: Toray Industries Inc. has developed an endotoxin removal cartridge (Toraymyxin) composed of a polymyxin B immobilized, fibrous adsorbent. Toraymyxin been listed as blood purification medical device for to be reimbursed by the Japanese national health insurance since 1994. can applied patients with endotoxemia or suspected gram-negative infection, which fulfilll conditions Systemic Inflammatory Response Syndrome (SIRS) and have septic shock demanding vasopressor infusion. Since 1994, over 30,000 received this treatment. The safety confirmed improvement hemodynamic dysfunction shown major benefit. Infection resulting from acute abdominal condition requiring surgery one good indications Toraymyxin. Further studies are now ongoing establish treatment options treat sepsis clarify mechanisms involved in therapy.

参考文章(15)
RICHARD AMERLINC, COSME CRUZ, Experimental study of extracorporeal perfusion for septic shock. Asaio Journal. ,vol. 39, ,(1993) , 10.1097/00002480-199307000-00130
Bertrand L. Jaber, Tyler W. Barrett, Miguel Cendoroglo Neto, Sumuk Sundaram, Andrew J. King, Brian J. G. Pereira, Removal of cytokine inducing substances by polymyxin-B immobilized polystyrene-derivative fibers during in vitro hemoperfusion of 10% human plasma containing Staphylococcus aureus challenge. Asaio Journal. ,vol. 44, pp. 48- 53 ,(1998) , 10.1097/00002480-199801000-00011
Kenji Tsushima, Keishi Kubo, Tomonobu Koizumi, Hiroshi Yamamoto, Keisaku Fujimoto, Kazuhiko Hora, Yutaka Kan-nou, Direct hemoperfusion using a polymyxin B immobilized column improves acute respiratory distress syndrome. Journal of Clinical Apheresis. ,vol. 17, pp. 97- 102 ,(2002) , 10.1002/JCA.10019
Bertrand L. Jaber, Tyler W. Barrett, Miguel Cendoroglo Neto, Sumuk Sundaram, Andrew J. King, Brian J. G. Pereira, Endotoxin removal by polymyxin-B immobilized polystyrene-derivative fibers during in vitro hemoperfusion of 10% human plasma. Asaio Journal. ,vol. 44, pp. 54- 61 ,(1998) , 10.1097/00002480-199801000-00012
Kohei Uriu, Akihiko Osajima, Kinya Hiroshige, Hiroyuki Watanabe, Keiji Aibara, Yoshifumi Inada, Kayoko Segawa, Hiroshi Anai, Ichiro Takagi, Aki Ito, Masayuki Kamochi, Kazo Kaizu, Endotoxin removal by direct hemoperfusion with an adsorbent column using polymyxin B-immobilized fiber ameliorates systemic circulatory disturbance in patients with septic shock American Journal of Kidney Diseases. ,vol. 39, pp. 937- 947 ,(2002) , 10.1053/AJKD.2002.32767
Takayuki SUGIYAMA, Tsutomu KATAI, Misako OKITSU, Masahiro OHTAWA, Takehisa KODAMA, Naoaki KANAMORI, Eriko KINUGASA, Tadao AKIZAWA, Shozo KOSHIKAWA, Anticoagulant effect of a single bolus injection of parnaparin sodium (LHG) on a hemodialysis model in dogs Folia Pharmacologica Japonica. ,vol. 104, pp. 401- 412 ,(1994) , 10.1254/FPJ.104.401
Hirokazu Okada, Souichi Sugahara, Kenshi Moriwaki, Mitsuru Arai, Yoshihiko Kanno, Hiromichi Suzuki, Hironori Nemoto, Hidetomo Nakamoto, Newly developed immobilized polymyxin B fibers improve the survival of patients with sepsis. Blood Purification. ,vol. 19, pp. 361- 369 ,(2001) , 10.1159/000046966
Fabrice Zeni, Bradley Freeman, Charles Natanson, Anti-inflammatory therapies to treat sepsis and septic shock: a reassessment. Critical Care Medicine. ,vol. 25, pp. 1095- 1100 ,(1997) , 10.1097/00003246-199707000-00001
B. Beutler, A. Poltorak, The search for Lps: 1993-1998. Journal of Endotoxin Research. ,vol. 6, pp. 269- 293 ,(2000) , 10.1179/096805100101532153