A simple quantitative HPLC assay for ifosfamide in biological fluids.

作者: Jennifer M. Margison , P. M. Wilkinson , T. Cerny , N. Thatcher

DOI: 10.1002/BMC.1130010303

关键词: Gas chromatographyChromatographyHigh-performance liquid chromatographyChemistryIfosfamideStandard curveBiological specimenReversed-phase chromatographyPharmacokineticsDetection limit

摘要: A high performance liquid chromatography method is described for measuring Ifosfamide (I) in human serum. This involves solvent extraction, reverse phase HPLC and UV detection at 190 nm. Standard curves of peak height × detector sensitivity versus I concentration serum were linear with a lower limit 100 ng/ml. Authentic 14C-labelled cochromatographed standard found from treated patients. The concentration-time determined by both gas indistinguishable. We conclude that this suitable determining pharmacokinetics biological specimens.

参考文章(5)
T. Wagner, D. Heydrich, T. Jork, G. Voelcker, H. J. Hohorst, Comparative study on human pharmacokinetics of activated ifosfamide and cyclophosphamide by a modified fluorometric test. Journal of Cancer Research and Clinical Oncology. ,vol. 100, pp. 95- 104 ,(1981) , 10.1007/BF00405906
C. Pantarotto, A. Bossi, G. Belvedere, A. Martini, M.G. Donelli, A. Frigerio, Quantitative GLC Determination of Cyclophosphamide and Isophosphamide in Biological Specimens Journal of Pharmaceutical Sciences. ,vol. 63, pp. 1554- 1558 ,(1974) , 10.1002/JPS.2600631014
Mack R. Holdiness, Lee Roy Morgan, Electron-capture--gas chromatographic analysis of ifosfamide in human plasma and urine. Journal of Chromatography B: Biomedical Sciences and Applications. ,vol. 275, pp. 432- 435 ,(1983) , 10.1016/S0378-4347(00)84392-3
W.P. Brade, K. Herdrich, M. Varini, Ifosfamide-pharmacology, safety and therapeutic potential Cancer Treatment Reviews. ,vol. 12, pp. 1- 47 ,(1985) , 10.1016/0305-7372(85)90011-8