作者: Thedford P. Dirkse
DOI: 10.1016/0013-4686(91)85002-O
关键词: Analytical chemistry 、 Voltage 、 Peroxide 、 Electrode material 、 Chemistry 、 Electrode potential 、 Open-circuit voltage 、 Electrode 、 Electrochemistry 、 General Chemical Engineering
摘要: Abstract The open circuit voltages (OCVs) of small AgZn cells were measured throughout a charge—discharge cycle. This work was supplemented by measuring the OCV Ag disk charged at constant potential. results are consistent with conclusion stated earlier that during charging silver—alkaline electrode silver is oxidized to divalent, not trivalent, state. There also evidence for peroxide formation latter stages process.