Placement of FACTS controllers for enhancing power system loadability

作者: JG Singh , SN Singh , SC Srivastava , None

DOI: 10.1109/POWERI.2006.1632526

关键词: Sensitivity (control systems)Flexible AC transmission systemTransmission systemUnified power flow controllerThyristorElectric power systemPower flowEngineeringTransmission (telecommunications)Control engineeringControl theory

摘要: The continuous change in power demand and supply altered the flow patterns transmission networks such a way that some of corridors are lightly loaded get over loaded. This raises serious challenge operating system secure reliable manner. To cope with this problem flexible AC systems (FACTS) is used. It plays very important role improving performance but these devices costly need to be placed optimally system. paper suggests new sensitivity based approach locate thyristor controlled series compensator (TCSC) unified controller (UPFC) for enhancing loadability. effectiveness proposed method tested illustrated on 5-bus IEEE 14-bus systems.

参考文章(15)
Bruce F. Wollenberg, Allen J. Wood, Power Generation, Operation, and Control ,(1984)
A. Sharma, S. Chanana, S. Parida, Combined optimal Location of FACTS controllers and loadability enhancement in competitive electricity markets using MILP IEEE Power Engineering Society General Meeting, 2005. pp. 670- 677 ,(2005) , 10.1109/PES.2005.1489247
S.N. Singh, I. Erlich, Locating unified power flow controller for enhancing power system loadability 2005 International Conference on Future Power Systems. ,(2005) , 10.1109/FPS.2005.204219
E.V. Larsen, N.W. Miller, S.L. Nilsson, S.R. Lindgren, Benefits of GTO-based compensation systems for electric utility applications IEEE Transactions on Power Delivery. ,vol. 7, pp. 2056- 2064 ,(1992) , 10.1109/61.157009
Sung-Hwan Song, Jung-Uk Lim, Seung-Il Moon, Installation and operation of FACTS devices for enhancing steady-state security Electric Power Systems Research. ,vol. 70, pp. 7- 15 ,(2004) , 10.1016/J.EPSR.2003.11.009
Preecha Preedavichit, S.C. Srivastava, Optimal reactive power dispatch considering FACTS devices Electric Power Systems Research. ,vol. 46, pp. 251- 257 ,(1998) , 10.1016/S0378-7796(98)00075-3
L.L. Freris, A.M. Sasson, Investigation of the load-flow problem Proceedings of the Institution of Electrical Engineers. ,vol. 115, pp. 1459- 1470 ,(1967) , 10.1049/PIEE.1968.0260
N.G. Hingorani, Flexible AC transmission IEEE Spectrum. ,vol. 30, pp. 40- 45 ,(1993) , 10.1109/6.206621
A KAZEMI, B BADRZADEH, Modeling and simulation of SVC and TCSC to study their limits on maximum loadability point International Journal of Electrical Power & Energy Systems. ,vol. 26, pp. 619- 626 ,(2004) , 10.1016/J.IJEPES.2004.04.008
S.N. Singh, A.K. David, Congestion management by optimising FACTS device location international conference on electric utility deregulation and restructuring and power technologies. pp. 23- 28 ,(2000) , 10.1109/DRPT.2000.855633