Understanding surface discharge activity in copper sulphide diffused oil impregnated pressboard under AC voltages

作者: R. Sarathi , I. Merin Sheema , J. Rajan

DOI: 10.1109/TDEI.2013.004039

关键词: PressboardRise timeChemistrySurface chargeEnergy-dispersive X-ray spectroscopyTransformer oilPartial dischargeCurrent (fluid)CopperAnalytical chemistry

摘要: The surface discharge injected current were measured by using High Frequency Current Transformer (HFCT). It is observed that the rise time of pulse about 800ps. In addition, pulses has not altered in copper sulphide (CuS) diffused Oil Impregnated Pressboard (OIP) material, but width signal increased with increase amount diffusion into pressboard. confirmed radiates Ultra (UHF) and dominant frequency UHF formed due to 0.9 GHz. characteristic contents activity same virgin pressboard material. inception voltage high specimen compared oil impregnated paper insulating material irrespective it. Phase Resolved Partial Discharge (PRPD) analysis indicates at point inception, occurs peak applied AC when magnitude increased, rising portion voltage. characteristics discharges are noticed ageing time, a reduction partial observed. Attenuated total reflectance Fourier transform infra-red spectroscopy (ATR-FTIR) was carried out understand changes occur degraded zone discharges. measurement charge increases accumulation. Energy Dispersive Spectroscopy (EDS) confirms presence sulphur aged Atomic Absorption (AAS) results indicate content have time.

参考文章(41)
N. Izeki, A. Kurahashi, K. Matsuura, Behavior of Oil Corona and Damage of Transformer Insulation IEEE Transactions on Power Apparatus and Systems. ,vol. 90, pp. 2330- 2338 ,(1971) , 10.1109/TPAS.1971.293081
A. Beroual, L. Kebbabi, E.A. Al-Ammar, M.I. Qureshi, Analysis of creeping discharges activity at solid/liquid interfaces subjected to ac voltage Iet Generation Transmission & Distribution. ,vol. 5, pp. 973- 978 ,(2011) , 10.1049/IET-GTD.2010.0598
Junhao Li, Wenrong Si, Xiu Yao, Yanming Li, Measurement and simulation of partial discharge in oil impregnated pressboard with an electrical aging process Measurement Science and Technology. ,vol. 20, pp. 105701- ,(2009) , 10.1088/0957-0233/20/10/105701
I. Fofana, A. Bouaïcha, M. Farzaneh, Characterization of aging transformer oil–pressboard insulation using some modern diagnostic techniques European Transactions on Electrical Power. ,vol. 21, pp. 1110- 1127 ,(2011) , 10.1002/ETEP.499
Marek Florkowski, Jakub Furgal, Piotr Pajak, Analysis of fast transient voltage distributions in transformer windings under different insulation conditions IEEE Transactions on Dielectrics and Electrical Insulation. ,vol. 19, pp. 1991- 1998 ,(2012) , 10.1109/TDEI.2012.6396957
V.M. Moreno-Villa, M.A. Ponce-Velez, E. Valle-Jaime, J.L. Fierro-Chávez, Effect of surface charge on hydrophobicity levels of insulating materials IEE Proceedings - Generation, Transmission and Distribution. ,vol. 145, pp. 675- 681 ,(1998) , 10.1049/IP-GTD:19982361
Jiaming Yan, Ruijin Liao, Lijun Yang, Jian Li, Bin Liu, Product analysis of partial discharge damage to oil-impregnated insulation paper Applied Surface Science. ,vol. 257, pp. 5863- 5870 ,(2011) , 10.1016/J.APSUSC.2011.01.125
S. Toyama, J. Tanimura, N. Yamada, E. Nagao, T. Amimoto, Highly sensitive detection method of dibenzyl disulfide and the elucidation of the mechanism IEEE Transactions on Dielectrics and Electrical Insulation. ,vol. 16, pp. 509- 515 ,(2009) , 10.1109/TDEI.2009.4815186
B. Lutz, J. Kindersberger, Surface charge accumulation on cylindrical polymeric model insulators in air: simulation and measurement IEEE Transactions on Dielectrics and Electrical Insulation. ,vol. 18, pp. 2040- 2048 ,(2011) , 10.1109/TDEI.2011.6118642