Quantifizierung der Schrumpfungskräfte des Kapselsacks — Eine experimentelle Studie

作者: J. Draeger , R. Guthoff , F. Abramo , G. K. Lang , W. Neumann

DOI: 10.1007/978-3-7091-9074-6_12

关键词:

摘要: Mit Hilfe eines elektronischen Dynamometers werden die zur Verformung von Linsenhaptiken erforderlichen Krafte mit hoher Prazision bestimmt.

参考文章(10)
J. Draeger, R. Guthoff, H. Wirt, W. Neumann, G. K. Lang, Experimentelle Untersuchungen mit neuem Linsenmaterial, neuer Geometrie, insbesondere zur Gewebsverträglichkeit im Tierversuch Springer, Berlin, Heidelberg. pp. 15- 19 ,(1988) , 10.1007/978-3-642-73191-4_5
Peter J. McDonnell, W. Richard Green, A.E. Maumenee, W. Jackson Iliff, Pathology of Intraocular Lenses in 33 Eyes Examined Postmortem Ophthalmology. ,vol. 90, pp. 386- 403 ,(1983) , 10.1016/S0161-6420(83)34558-9
George Baikoff, Insertion of the Simcoe posterior chamber lens into the capsular bag American Intra-Ocular Implant Society Journal. ,vol. 7, pp. 267- 269 ,(1981) , 10.1016/S0146-2776(81)80017-1
David J Apple, Nick Mamalis, James J Reidy, Linda C Novak, Joseph M Googe, D Katherine Loftfield, Randall J Olson, None, A comparison of ciliary sulcus and capsular bag fixation of posterior chamber intraocular lenses. American Intra-Ocular Implant Society Journal. ,vol. 11, pp. 44- 63 ,(1985) , 10.1016/S0146-2776(85)80115-4
Robert C. Drews, Christine Kreiner, Comparative study of the elasticity and memory of intraocular lens loops. Journal of Cataract and Refractive Surgery. ,vol. 13, pp. 525- 530 ,(1987) , 10.1016/S0886-3350(87)80106-2
Peter J. McDonnell, Arun Patel, W. Richard Green, Comparison of intracapsular and extracapsular cataract surgery. Histopathologic study of eyes obtained postmortem. Ophthalmology. ,vol. 92, pp. 1208- 1225 ,(1985) , 10.1016/S0161-6420(85)33875-7
Gerald D. Faulkner, Early experience with STAAR™ silicone elastic lens implants Journal of Cataract & Refractive Surgery. ,vol. 12, pp. 36- 39 ,(1986) , 10.1016/S0886-3350(86)80053-0
Peter J. McDonnell, Raymond Champion, W. Richard Green, Location and composition of haptics of posterior chamber intraocular lenses. Histopathologic study of postmortem eyes. Ophthalmology. ,vol. 94, pp. 136- 142 ,(1987) , 10.1016/S0161-6420(87)33485-2
C. F. Kreiner, Chemical and physical aspects of clinically applied silicones. Developments in ophthalmology. ,vol. 14, pp. 11- 19 ,(1987) , 10.1159/000414359
McDonnell Pj, Green Wr, Opacification of the posterior capsule. Transactions of the ophthalmological societies of the United Kingdom. ,vol. 104, pp. 727- 739 ,(1985)