作者: R.B.M. Sogbadji , B.J.B. Nyarko , E.H.K. Akaho , R.G. Abrefah
DOI: 10.1016/J.NUCENGDES.2009.12.020
关键词: Resonance 、 Nuclear physics 、 Neutron temperature 、 Neutron source 、 Neutron stimulated emission computed tomography 、 Neutron 、 Semiconductor detector 、 Analytical chemistry 、 Research reactor 、 Irradiation 、 Materials science 、 Nuclear and High Energy Physics 、 Mechanical engineering 、 Waste Management and Disposal 、 General Materials Science 、 Nuclear Energy and Engineering 、 Safety, Risk, Reliability and Quality
摘要: Abstract Nuclear constants for use in reactor activation analysis especially (n, γ) cross-sections and absolute gamma intensities, are known to show a rather large scatter literature. Thermal resonance the 75As γ)76As reaction is determined by method of foil using 55Mn γ)56Mn as reference reaction. The experimental sample with without cadmium cover 1-mm wall thickness was irradiated isotropic neutron field outer irradiation sites 7 Ghana Research Reactor-1 facility which miniature source designed Chinese. channel used has spectral parameter (α) found be (0.037 ± 0.001). induced activity measured ray spectrometry high purity germanium detector. A standard solution Arsenic analysis. necessary correction attenuation, thermal neutrons self-shielding effects were not taken into account during because they negligible. By defining cut-off energy 0.55 eV, result be: cross-section σ0 = (4.28 ± 0.19) b integral I0 = (61.88 ± 1.07) b.