作者: G. Nagy , G.A. Gerhardt , A.F. Oke , M.E. Rice , R.N. Adams
DOI: 10.1016/S0022-0728(85)80052-8
关键词: Nafion 、 Analytical chemistry 、 Ion exchange 、 Graphite electrode 、 Voltammetry 、 Microelectrode 、 Chemical engineering 、 Chemistry 、 Electrode
摘要: Abstract Very small Nafion-coated voltammetric electrodes are very advantageous for in vivo detection of catecholamine neurotransmitters. In this study their quantitative characteristics with regard to partitioning the catecholamines into Nafion film have been studied. The properties these compared larger graphite covered film.