作者: Hasila Jarimi , Mohd Nazari Abu Bakar , Mahmod Othman , Mahadzir Hj Din
DOI: 10.1016/J.RENENE.2015.07.014
关键词: Control theory 、 Thermal 、 Mean absolute percentage error 、 Solar simulator 、 MATLAB 、 Solar energy 、 Coefficient of determination 、 Nuclear engineering 、 Root mean square 、 Photovoltaic system 、 Engineering
摘要: Abstract This paper discusses theoretical and indoor experimental studies of a bi-fluid type photovoltaic/thermal PV/T solar collector. 2D steady-state analysis was developed computer simulation performed using MATLAB. Experiments were conducted for under the simulator at Solar Energy Research Lab UiTM Perlis, Malaysia. The test includes all three modes fluid operation same system, namely: air mode, water simultaneous mode air. results validated against methods error analysis: root mean square percentage deviation (RMSPD), absolute (MAPE), coefficient determination (R 2 ). On average, MAPE, RMSPD, R computed output temperature are approximately 0.92%, 1.19%, 0.98, respectively. Thus, we concluded that in good agreement. collector designed this study has variety applications as it can be operated different operation, model is useful modelling without further modification.