A Continuous Loading Apparatus for Measuring Three-dimensional Stiffness of Ankle-Foot Orthoses

作者: Paolo Cappa , Fabrizio Patanè , Giuseppe Di Rosa

DOI: 10.1115/1.2049313

关键词: Structural engineeringRotary stageRotationAnkleDisplacement (orthopedic surgery)Materials scienceReactionLoad cellStiffnessOrthoticsPhysiology (medical)Biomedical engineering

摘要: This paper describes a novel device to evaluate the mechanical properties of ankle foot orthoses (AFOs). The apparatus permits the application to AFOs of continuous three-dimensional (3D) movements between specified and settable endpoints. Using an x-y robot with a rotary stage and a six-component load cell, characteristic displacement versus reaction force curves can be generated and consequently the ankle moments can be determined as a function of dorsi/plantar flexion, inv/eversion and int/external rotation. Representative curves for two polypropylene lateral leaf AFOs, different in shape but produced for the same leg by a skilled orthotist, are presented to illustrate the capabilities of the novel testing system. The metrological investigation showed that the apparatus creates a highly repeatable data set (uncertainty ⩽1% FSO).

参考文章(22)
Narender P. Reddy, Tai-Ming Chu, Stress distribution in the ankle-foot orthosis used to correct pathological gait. Journal of Rehabilitation Research and Development. ,vol. 32, pp. 349- 360 ,(1995)
Dan Deitz, Optimizing orthotic designs with FEA Mechanical Engineering. ,vol. 119, pp. 70- 71 ,(1997)
Ge Wu, Sorin Siegler, Paul Allard, Chris Kirtley, Alberto Leardini, Dieter Rosenbaum, Mike Whittle, Darryl D D’Lima, Luca Cristofolini, Hartmut Witte, Oskar Schmid, Ian Stokes, ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—part I: ankle, hip, and spine Journal of Biomechanics. ,vol. 35, pp. 543- 548 ,(2002) , 10.1016/S0021-9290(01)00222-6
Masahiro Nagaya, Shoehorn-type ankle-foot orthoses: Prediction of flexibility☆ Archives of Physical Medicine and Rehabilitation. ,vol. 78, pp. 82- 84 ,(1997) , 10.1016/S0003-9993(97)90015-0
Thomas R. Lunsford, Thomas Ramm, Joseph A. Miller, Viscoelastic Properties of Plastic Pediatric AFOs Jpo Journal of Prosthetics and Orthotics. ,vol. 6, pp. 3- 9 ,(1994) , 10.1097/00008526-199400610-00002
D. J. Leone, A Structural Model for Molded Thermoplastic Ankle-Foot Orthoses Journal of Biomechanical Engineering. ,vol. 109, pp. 305- 310 ,(1987) , 10.1115/1.3138685
Sumiko Yamamoto, Masahiko Ebina, Mitsuo Iwasaki, Shigeru Kubo, Hideo Kawai, Takeo Hayashi, Comparative Study of Mechanical Characteristics of Plastic AFOs Jpo Journal of Prosthetics and Orthotics. ,vol. 5, ,(1993) , 10.1097/00008526-199304000-00009
T.-M. Chu, N.P. Reddy, J. Padovan, Three-dimensional finite element stress analysis of the polypropylene, ankle-foot orthosis: static analysis. Medical Engineering & Physics. ,vol. 17, pp. 372- 379 ,(1995) , 10.1016/1350-4533(95)97317-I