Optical fiber reflectance sensor coupled to a multisyringe flow injection system for preconcentration and determination of 1-naphthylamine in water samples

作者: JL Guzmán Mar , L López Martínez , PL López de Alba , JE Castrejón Durán , V Cerdà Martín

DOI: 10.1016/J.ACA.2005.12.049

关键词: ChromatographyCalibration curveNitriteChemistryRepeatabilityStandard curveDetection limitGriess testSpectrophotometryAnalytical chemistryNitrous acid

摘要: Abstract A novel optical fiber reflectance sensor is coupled to a multisyringe flow injection system (MSFIA) for the preconcentration and determination of 1-naphthylamine (NPA) in water samples using C18 disks (octadecyl groups). NPA, being first-class carcinogen, important from toxicological point view and, therefore, its quantification considerable interest. In this study, Griess reaction used sensitive selective spectrophotometric NPA. The involves conversion nitrite into nitrous acid acidic medium followed by diazotization sulphanilic formation diazonium salt. salt then combined with NPA form 4-(sulphophenylazo)-1-naphthylamine, an azo dye. This compound subsequently retained onto disk detection at 540 nm, it eluted methanol (80%, v/v), so that regenerated subsequent experiments. Under established optimum conditions, calibration graph was constructed. Good linearity observed within concentration range 10 160 μg l −1 . lineal regression equation  = (0.0027 ± 0.0001) [NPA] + (0.0296 ± 0.0047), r  = 0.9991; relative standard deviation values obtained analysis 10, 80 are 4.7, 1.2 0.6%, respectively. mean value errors concentrations 80, 3.4, 0.9 0.4%, limits were 1.1 3.7 μg l sampling throughput 14 injections per hour achieved. repeatability calculated five different E rel  = 2.8%. proposed technique has been validated replicate ( n  = 6) several spiked giving satisfactory results.

参考文章(19)
M. D. Luque de Castro, Miguel Valcárcel Cases, Flow-injection analysis : principles and applications E. Horwood , Halsted Press. ,(1987)
J. Ṙuz̆ic̆ka, E.H. Hansen, Flow injection analyses Analytica Chimica Acta. ,vol. 78, pp. 145- 157 ,(1975) , 10.1016/S0003-2670(01)84761-9
Manuel Miró, Wolfgang Frenzel, Vı́ctor Cerdà, José Manuel Estela, Determination of ultratraces of nitrite by solid-phase preconcentration using a novel flow-through spectrophotometric optrode Analytica Chimica Acta. ,vol. 437, pp. 55- 65 ,(2001) , 10.1016/S0003-2670(01)00962-X
A. Salinas-Castillo, J.F. Fernández-Sánchez, A. Segura-Carretero, A. Fernández-Gutiérrez, A facile flow-through phosphorimetric sensing device for simultaneous determination of naptalam and its metabolite 1-naphthylamine Analytica Chimica Acta. ,vol. 522, pp. 19- 24 ,(2004) , 10.1016/J.ACA.2004.06.044
V Cerdà, J.M Estela, R Forteza, A Cladera, E Becerra, P Altimira, P Sitjar, Flow techniques in water analysis Talanta. ,vol. 50, pp. 695- 705 ,(1999) , 10.1016/S0039-9140(99)00196-4
Jaromir Růžička, Elo H. Hansen, Optosensing at active surfaces — a new detection principle in flow injection analysis Analytica Chimica Acta. ,vol. 173, pp. 3- 21 ,(1985) , 10.1016/S0003-2670(00)84939-9
Jaromir Ruzicka, Graham D. Marshall, Sequential injection: a new concept for chemical sensors, process analysis and laboratory assays Analytica Chimica Acta. ,vol. 237, pp. 329- 343 ,(1990) , 10.1016/S0003-2670(00)83937-9