Arthroplasty of the shoulder in rheumatoid arthritis with rotator cuff dysfunction.

作者: M. Woodruff , A. Cohen , J. Bradley

DOI: 10.1007/S00264-002-0406-9

关键词: ComplicationShouldersSurgeryRotator cuffRheumatoid arthritisMedicineOrthopedic surgeryRadiographyProsthesisArthroplasty

摘要: We carried out a retrospective analysis of 17 total shoulder replacements using the reversed Delta III prosthesis in patients with rheumatoid arthritis glenohumeral joint complicated by rotator cuff dysfunction. Outcome was assessed Constant-Murley scoring system. In addition, general health status Short Form Health Survey and radiographical prostheses undertaken. Mean age at time surgery 64 years. Thirteen shoulders were followed up for more than 5 years (mean 87 months). Median score 59.0; median scores 33.40 49.36 physical mental components respectively. Radiographical revealed evidence lucencies about humeral component all cases glenoid five cases. Despite good clinical results, high incidence is concern.

参考文章(18)
Cofield Rh, Uncemented total shoulder arthroplasty. A review. Clinical Orthopaedics and Related Research. pp. 86- 93 ,(1994)
MICHAEL A. WIRTH, CHARLES A. ROCKWOOD, Complications of total shoulder-replacement arthroplasty. Journal of Bone and Joint Surgery, American Volume. ,vol. 78, pp. 603- 616 ,(1996) , 10.2106/00004623-199604000-00018
MELVIN POST, MICHAEL JABLON, Constrained total shoulder arthroplasty. Long-term follow-up observations. Clinical Orthopaedics and Related Research. pp. 109- 116 ,(1983) , 10.1097/00003086-198303000-00014
RAYMOND SEVERT, BERT J. THOMAS, MICHAEL J. TSENTER, HARLAN C. AMSTUTZ, J. MICHAEL KABO, The influence of conformity and constraint on translational forces and frictional torque in total shoulder arthroplasty. Clinical Orthopaedics and Related Research. pp. 151- 158 ,(1993) , 10.1097/00003086-199307000-00019
John Brems, The glenoid component in total shoulder arthroplasty Journal of Shoulder and Elbow Surgery. ,vol. 2, pp. 47- 54 ,(1993) , 10.1016/S1058-2746(09)80138-9
Oskar de Leest, Piet M. Rozing, Leonard A. Rozendaal, Frans C.T. van der Helm, Influence of glenohumeral prosthesis geometry and placement on shoulder muscle forces. Clinical Orthopaedics and Related Research. ,vol. 330, pp. 222- 233 ,(1996) , 10.1097/00003086-199609000-00030
Marcus J.K. Bankes, John E. Crossman, Roger J.H. Emery, A standard method of shoulder strength measurement for the Constant score with a spring balance. Journal of Shoulder and Elbow Surgery. ,vol. 7, pp. 116- 121 ,(1998) , 10.1016/S1058-2746(98)90220-8
Roger G. Pollock, Efrain D. Deliz, Stephen J. McIlveen, Evan L. Flatow, Louis U. Bigliani, Prosthetic replacement in rotator cuff—deficient shoulders Journal of Shoulder and Elbow Surgery. ,vol. 1, pp. 173- 186 ,(1992) , 10.1016/1058-2746(92)90011-Q
C. R. Constant, A. H. G. Murley, A clinical method of functional assessment of the shoulder. Clinical Orthopaedics and Related Research. ,vol. 214, pp. 160- 164 ,(1987) , 10.1097/00003086-198701000-00023
N. K. POPPEN, P. S. WALKER, Forces at the glenohumeral joint in abduction. Clinical Orthopaedics and Related Research. ,vol. 135, pp. 165- 170 ,(1978) , 10.1097/00003086-197809000-00035