The Ellipsoidheart in Total Artificial Heart Replacement

作者: F. Unger

DOI: 10.1007/978-3-642-67268-2_37

关键词: Artificial heartSalt lakeHeart failureHeart transplantationProsthesisFixed frequencySurgeryLimitingMedicine

摘要: Despite the fact that in 1969 total artificial heart (TAH) was applied clinically for 64 h orthotopic position [3], long-term surviving TAH recipient calves were difficult to achieve. is coming of age and can now be discussed as a temporary device combined with transplantation [6, 15]. This based on have survived an most recently Salt Lake City 7 months [6], Cleveland 5 [21], Berlin [9], Her-shey, 3 [12], Vienna, 1½ [23], Houston ¾ month. All cardiac prostheses are energized by external pneumatic power supply transcutaneous driving lines. The main limiting factors following: 1) Thromboembolization design, biomaterial, valves. 2) Dysregulation prosthesis resulting possible chronic left right failure syndrome.

参考文章(13)
R. Kellner, F. Unger, IR-Spektroskopische Charakterisierung der BlutvertrÄglichkeit von Polyurethan-Silicon-Copolymeren Fresenius Journal of Analytical Chemistry. ,vol. 283, pp. 349- 355 ,(1977) , 10.1007/BF00442354
Don B. Olsen, Felix Unger, Hartmut Oster, John Lawson, Thomas Kessler, Jack Kolff, W.J. Kolff, Thrombus generation within the artificial heart. The Journal of Thoracic and Cardiovascular Surgery. ,vol. 70, pp. 248- 255 ,(1975) , 10.1016/S0022-5223(19)40347-4
Prophet Ga, Donachy Jh, O'Bannon W, Phillips Wm, Brighton Ja, Ferrari O, Pierce Ws, A comparison of three ventricles used for left ventricular bypass in the calf. Asaio Journal. ,vol. 22, pp. 450- ,(1976)
R. J. Kiraly, R. Arconti, D. Hillegass, H. Harasaki, Y. Nose, High flex rubber for blood pump diaphragms. Asaio Journal. ,vol. 23, pp. 127- 132 ,(1977) , 10.1097/00002480-197700230-00036
D. L. Landis, W. S. Pierce, G. Rosenberg, J. H. Donachy, J. A. Brighton, Long-term in vivo automatic electronic control of the artificial heart. Asaio Journal. ,vol. 23, pp. 519- 524 ,(1977) , 10.1097/00002480-197700230-00138
R. K. Jarvik, D. B. Olsen, T. R. Kessler, J. Lawson, J. English, W. J. Kolff, Criteria for human total artificial heart implantation based on steady state animal data. Asaio Journal. ,vol. 23, pp. 535- 542 ,(1977) , 10.1097/00002480-197700230-00142
M. Szycher, V. Poirier, J. Keiser, Selection of materials for ventricular assist pump development and fabrication. Asaio Journal. ,vol. 23, pp. 116- 124 ,(1977) , 10.1097/00002480-197700230-00034
N. Tsushima, S. Kasai, I. Koshino, G. Jacobs, N. Morinaga, T. Washizu, R. Kiraly, Y. Nosé, 145 days survival of calf with total artificial heart (TAH). Asaio Journal. ,vol. 23, pp. 526- 533 ,(1977) , 10.1097/00002480-197700230-00140
Jeffrey L. Peters, Stephen R. Greenhalgh, Jerrold L. Foote, Thomas C. Militano, W. J. Kolff, Comparative evaluation of artificial ventricles in the United States. Biomaterials, medical devices, and artificial organs. ,vol. 3, pp. 1- 24 ,(1975) , 10.3109/10731197509118611