作者: M. Sigit Darmawan , Ridho Bayuaji , N. A. Husin , R. B. Anugraha
DOI: 10.1155/2014/970393
关键词: Service life 、 Forensic engineering 、 Water cooling 、 Civil engineering 、 Test (assessment) 、 Engineering 、 Safety factor
摘要: This paper deals with the assessment of remaining service life a cooling water intake concrete structure (CWICS) subjected to corrosion due chloride attacks. Field and laboratory tests were performed determine current existing condition structure. Both destructive nondestructive employed obtain parameter needed for assessment. Based on test results, structural analysis was carried out safety factor CWICS determined. From analysis, it found that most elements had greater than unity might fulfil its intended up year 2033. However, fewer require immediate strengthening extend their life.