A miniaturised analytical protocol for highly sensitive determination of bisphenol A in bottled drinking water

作者: Shivender Singh Saini , A. L. J. Rao , Baldev Singh , Ashok Kumar Malik

DOI: 10.1039/C5AY02172C

关键词: Extraction (chemistry)Bisphenol ABisphenol SWater qualityHigh-performance liquid chromatographyDetection limitChemistryChromatographyQuantitative analysis (chemistry)Highly sensitive

摘要: This paper proposes a novel, fast, reliable and miniaturised analytical protocol for highly sensitive determination of bisphenol A (BPA) in bottled drinking water. hybrid approach involves lucid expeditious combination micro-extraction packed syringe (MEPS) with high performance liquid chromatography coupled to an ultra-violet detector (HPLC-UV). The method was developed, optimised validated the BPA commercial water remarkable sensitivity picogram quantities (ppt level). important parameters MEPS procedure affecting extraction efficiency were optimized 50 cycles draw–eject sample speed 10 μl s−1 gave maximum peak area, time 0.998). Precision studies showed % RSD values less than 2% all selected concentrations. percentage recoveries range 97.50–97.57. limit detection (LOD) quantification (LOQ) 0.0416 pg ml−1 0.1248 BPA, respectively. proposed successfully applied quantitative analysis real beverage samples level 5.40 14.22 ml−1, acceptable (%) 3–9 is suitable routine monitoring water, regulatory purposes. Furthermore, this should also allow easy expansion quality records different related compounds like octyl nonyl phenol as well S F

参考文章(34)
K. Yekdeli Kermanshahi, R. Tabaraki, H. Karimi, M. Nikorazm, S. Abbasi, Classification of Iranian bottled waters as indicated by manufacturer’s labellings Food Chemistry. ,vol. 120, pp. 1218- 1223 ,(2010) , 10.1016/J.FOODCHEM.2009.11.067
Krishna Kumar Selvaraj, Govindaraj Shanmugam, Srimurali Sampath, D.G. Joakim Larsson, Babu Rajendran Ramaswamy, GC–MS determination of bisphenol A and alkylphenol ethoxylates in river water from India and their ecotoxicological risk assessment Ecotoxicology and Environmental Safety. ,vol. 99, pp. 13- 20 ,(2014) , 10.1016/J.ECOENV.2013.09.006
Mohamed Abdel-Rehim, Recent advances in microextraction by packed sorbent for bioanalysis Journal of Chromatography A. ,vol. 1217, pp. 2569- 2580 ,(2010) , 10.1016/J.CHROMA.2009.09.053
Muhammad Umar, Felicity Roddick, Linhua Fan, Hamidi Abdul Aziz, Application of ozone for the removal of bisphenol A from water and wastewater--a review. Chemosphere. ,vol. 90, pp. 2197- 2207 ,(2013) , 10.1016/J.CHEMOSPHERE.2012.09.090
Zhanlong Mei, Wei Qu, Yi Deng, Huaqin Chu, Jinxuan Cao, Feng Xue, Lei Zheng, Hani Said El-Nezamic, Yucheng Wu, Wei Chen, One-step signal amplified lateral flow strip biosensor for ultrasensitive and on-site detection of bisphenol A (BPA) in aqueous samples. Biosensors and Bioelectronics. ,vol. 49, pp. 457- 461 ,(2013) , 10.1016/J.BIOS.2013.06.006
Martin Adam, Petra Pavlíková, Andrea Čížková, Petra Bajerová, Karel Ventura, Microextraction by packed sorbent (MEPS) as a suitable selective method for l-ascorbic acid determination in beverages. Food Chemistry. ,vol. 135, pp. 1613- 1618 ,(2012) , 10.1016/J.FOODCHEM.2012.06.039
Andre Kim, Chun-Ri Li, Chun-Feng Jin, Keun Woo Lee, Sang-Hoon Lee, Kwang-Jae Shon, Nam Gyu Park, Dong-Kyoo Kim, Shin-Won Kang, Yoon-Bo Shim, Jang-Su Park, A sensitive and reliable quantification method for Bisphenol A based on modified competitive ELISA method. Chemosphere. ,vol. 68, pp. 1204- 1209 ,(2007) , 10.1016/J.CHEMOSPHERE.2007.01.079
Renata Wietecha-Posłuszny, Aneta Garbacik, Michał Woźniakiewicz, Agnieszka Moos, Marcin Wieczorek, Paweł Kościelniak, Application of microextraction by packed sorbent to isolation of psychotropic drugs from human serum Analytical and Bioanalytical Chemistry. ,vol. 402, pp. 2249- 2257 ,(2012) , 10.1007/S00216-011-5442-0