High range resolution ultrasound imaging of a human carotid artery using frequency domain interferometry

作者: Hirofumi Taki , Takuya Sakamoto , Makoto Yamakawa , Tsuyoshi Shiina , Toru Sato

DOI: 10.1109/ULTSYM.2011.0546

关键词: Adaptive beamformerAcousticsUltrasound imagingResolution (electron density)Vascular ultrasoundComputer scienceCarotid arteriesInterferometryUltrasonographyFrequency domainHigh range resolution

摘要: In this study, we propose a high range resolution ultrasound imaging method using frequency domain interferometry with adaptive beamforming technique. We employ multiple reference signals to compensate the variation of vessel wall slope. The proposed succeeded acquire carotid artery image normal living human subject, where was applied single frame IQ data obtained by commercial ultrasonographic device. This result verified capability improve in ultrasonography. believe will largely progress medical diagnostics vascular ultrasound.

参考文章(8)
H. Taki, K. Taki, T. Sakamoto, M. Yamakawa, T. Shiina, M. Kudo, T. Sato, High Range Resolution Ultrasonographic Vascular Imaging Using Frequency Domain Interferometry With the Capon Method IEEE Transactions on Medical Imaging. ,vol. 31, pp. 417- 429 ,(2012) , 10.1109/TMI.2011.2170847
Hirofumi Taki, Kousuke Taki, Takuya Sakamoto, Makoto Yamakawa, Tsuyoshi Shiina, Toru Sato, High range resolution medical acoustic vascular imaging with frequency domain interferometry international conference of the ieee engineering in medicine and biology society. ,vol. 2010, pp. 5298- 5301 ,(2010) , 10.1109/IEMBS.2010.5626325
Stanley P. Azen, Wendy J. Mack, Linda Cashin-Hemphill, Laurie LaBree, Anne M. Shircore, Robert H. Selzer, David H. Blankenhorn, Howard N. Hodis, Progression of Coronary Artery Disease Predicts Clinical Coronary Events Long-term Follow-up From the Cholesterol Lowering Atherosclerosis Study Circulation. ,vol. 93, pp. 34- 41 ,(1996) , 10.1161/01.CIR.93.1.34
Paul A Magnin, Olaf T von Ramm, Frederick L Thurstone, Frequency compounding for speckle contrast reduction in phased array images Ultrasonic Imaging. ,vol. 4, pp. 267- 281 ,(1982) , 10.1016/0161-7346(82)90011-6
J. Capon, High-resolution frequency-wavenumber spectrum analysis Proceedings of the IEEE. ,vol. 57, pp. 1408- 1418 ,(1969) , 10.1109/PROC.1969.7278
J.A. Mann, W.F. Walker, A constrained adaptive beamformer for medical ultrasound: initial results internaltional ultrasonics symposium. ,vol. 2, pp. 1807- 1810 ,(2002) , 10.1109/ULTSYM.2002.1192650
B. Widrow, K. Duvall, R. Gooch, W. Newman, Signal cancellation phenomena in adaptive antennas: Causes and cures IEEE Transactions on Antennas and Propagation. ,vol. 30, pp. 469- 478 ,(1982) , 10.1109/TAP.1982.1142804
O.L. Frost, An algorithm for linearly constrained adaptive array processing Proceedings of the IEEE. ,vol. 60, pp. 926- 935 ,(1972) , 10.1109/PROC.1972.8817