Acetylcholinesterase Inhibition-Based Biosensor for Aluminum(III) Chronoamperometric Determination in Aqueous Media

作者: Miriam Barquero-Quirós , Olga Domínguez-Renedo , Maria Alonso-Lomillo , María Arcos-Martínez

DOI: 10.3390/S140508203

关键词: AmperometryBiosensorSubstrate (chemistry)ReproducibilityColloidal goldNuclear chemistryTap waterAnalytical chemistryDetection limitChemistryConductometry

摘要: A novel amperometric biosensor for the determination of Al(III) based on inhibition enzyme acetylcholinesterase has been developed. The immobilization was performed screen-printed carbon electrodes modified with gold nanoparticles. oxidation signal acetylthiocholine iodide substrate affected by presence ions leading to a decrease in current. developed system detection limit 2.1 ± 0.1 μM Al(III). reproducibility method is 8.1% (n = 4). Main interferences include Mo(VI), W(VI) and Hg(II) ions. successfully applied spiked tap water . analysis certified standard reference material also carried out. Both results agree values considering respective associated uncertainties.

参考文章(45)
Olga Domínguez Renedo, M. Julia Arcos Martínez, A novel method for the anodic stripping voltammetry determination of Sb(III) using silver nanoparticle-modified screen-printed electrodes Electrochemistry Communications. ,vol. 9, pp. 820- 826 ,(2007) , 10.1016/J.ELECOM.2006.11.016
M.A. Alonso-Lomillo, C. Yardimci, O. Domínguez-Renedo, M.J. Arcos-Martínez, CYP450 2B4 covalently attached to carbon and gold screen printed electrodes by diazonium salt and thiols monolayers. Analytica Chimica Acta. ,vol. 633, pp. 51- 56 ,(2009) , 10.1016/J.ACA.2008.11.033
Shaun D. Thomas, David E. Davey, Dennis E. Mulcahy, Christopher W. K. Chow, Indirect Amperometric Detection of Aluminium by Flow Injection Analysis Using DASA as Ligand Analytical Letters. ,vol. 38, pp. 133- 147 ,(2005) , 10.1081/AL-200043469
Olga Domínguez Renedo, M. Julia Arcos Martínez, Anodic stripping voltammetry of antimony using gold nanoparticle-modified carbon screen-printed electrodes. Analytica Chimica Acta. ,vol. 589, pp. 255- 260 ,(2007) , 10.1016/J.ACA.2007.02.069
Olga Domínguez-Renedo, M. Asunción Alonso-Lomillo, Pedro Recio-Cebrián, M. Julia Arcos-Martínez, Screen-printed acetylcholinesterase-based biosensors for inhibitive determination of permethrin Science of The Total Environment. ,vol. 426, pp. 346- 350 ,(2012) , 10.1016/J.SCITOTENV.2012.03.042
Lídia B. Santos, Maisa T.F. de Souza, Alexandre T. Paulino, Edivaldo E. Garcia, Eurica M. Nogami, Juliana C. Garcia, Nilson E. de Souza, Determination of aluminum in botanical samples by adsorptive cathodic stripping voltammetry as Al-8-hydroxyquinoline complex Microchemical Journal. ,vol. 112, pp. 50- 55 ,(2014) , 10.1016/J.MICROC.2013.09.016
Fuping ZHANG, Shuping BI, Jian LIU, Xiaodi YANG, Xianlong WANG, Li YANG, Tsing YU, Yijun CHEN, Lemei DAI, Tianming YANG, Application of dopamine as an electroactive ligand for the determination of aluminum in biological fluids. Analytical Sciences. ,vol. 18, pp. 293- 299 ,(2002) , 10.2116/ANALSCI.18.293
Yu-Chen Tsai, Siao-Yun Chen, Chen-An Lee, Amperometric cholesterol biosensors based on carbon nanotube–chitosan–platinum–cholesterol oxidase nanobiocomposite Sensors and Actuators B: Chemical. ,vol. 135, pp. 96- 101 ,(2008) , 10.1016/J.SNB.2008.07.025